10 Compaq StorageWorks Fibre Channel SAN Switch 16 Release Notes
SWCC
SWCC has the capability to log SNMP trap information (error and status
events) occurring on the switch into the Windows NT application Event log.
To enable this capability the following parameters must be set on the switch:
swEventTrapLevel: (0..5)—must be set for a severity level from 0 to 5
q
0 – none
q
1 – critical
q
2 – error
q
3 – warning
q
4 – informational
q
5 – debug
NOTE: Additional information is provided in the Compaq StorageWorks Fibre Channel SAN
Switch Management Guide.
authTrapsEnabled: (true, t, false, f)—must be set to "true" or "t" to
enable sending of traps
NOTE: This parameter is set to "true" or "t" by default.
These parameters can be set by using the switch telnet interface along with the
agtcfgSet Telnet command.