2-port SMIC Rotary Switch Positions

Table 5-4 shows the 2-port SMIC serial signal assignments. The position of the rotary switch determines
the port assignments. Although the rotary switch has 8 positions, only 1 of 2 positions can be selected.
The rotary switch position should be unique for each mobile interface card (MIC) card.
Table 5-4
Rotary Switch Position
0
1

SMIC LED Signals

Table 5-5
functions. Serial 2 and Serial 3 apply to the 4-port SMIC only.
Table 5-5
LED
SERIAL0 ACTIVITY
SERIAL0 LINK
SERIAL1 ACTIVITY
SERIAL1 LINK
SERIAL2 ACTIVITY
SERIAL2 LINK
SERIAL3 ACTIVITY
SERIAL3 LINK
Cisco 3200 Series Router Hardware Reference
5-4
2-port SMIC Rotary Switch Positions and Serial Set Signal Assignments
MIC Slot
1
2
shows the LED signals that are supported on the SMIC, along with the corresponding
SMIC LED Functions
Function
Blinks once when a packet is either transmitted from or received on Serial 0.
Originates from Header 5.
Indicates the status of Serial 0. Originates from Header 5. The LED is on
when a serial port is in DTE mode, and when the data set ready (DSR), data
carrier detect (DCD), and clear to send (CTS) signals are detected. The LED
is on when a serial port is in DCE mode, and when the data terminal ready
(DTR) and request to send (RTS) signals are detected.
Blinks once when a packet is either transmitted from or received on Serial 1.
Originates from Header 5.
Indicates the status of Serial 1. Originates from Header 5. The LED is on
when the serial port is in DTE mode, and when the DSR, DCD, and CTS
signals are detected. The LED is on when the serial port is in DCE mode, and
when the DTR and RTS signals have been detected.
Blinks once when a packet is either transmitted from or received on Serial 2.
Originates from Header 2.
Indicates the status of Serial 2. Originates from Header 2. The LED is on
when the serial port is in DTE mode, and when the DSR, DCD, and CTS
signals are detected. The LED is on when the serial port is in DCE mode, and
when the DTR and RTS signals have been detected.
Blinks once when a packet is either transmitted FROM or received on
Serial 3. Originates from Header 2.
Indicates the status of Serial 3. originates from Header 2. The LED is on
when the serial port is in DTE mode, and when the DSR, DCD, and CTS
signals are detected. The LED is on when the serial port is in DCE mode, and
when the DTR and RTS signals have been detected.
Signal Assignments
Serial 1/0 Serial 1/1 Serial 1/2 Serial 1/3
Serial 2/0 Serial 2/1 Serial 2/2 Serial 2/3
Chapter 5
Serial Mobile Interface Card