Cisco CISCO7206 Regulatory Compliance And Safety Information Manual

7200 series routers
Hide thumbs Also See for CISCO7206:

Advertisement

Quick Links

Doc. No.
78-3419-02
Regulatory Compliance and Safety Information
for the Cisco 7200 Series Routers
Product Numbers: CISCO7206, CISCO7206-DC, CISCO7204, CISCO7204-DC
This publication provides international agency compliance, safety, and statutory information for
wide area network (WAN) interfaces for the Cisco 7200 series routers. This publication also provides
translations for the safety warnings in the Cisco 72xx Installation and Configuration Guide that
shipped with your Cisco 7200 series router.
Use the information in this publication in conjunction with the Cisco 72xx Installation and
Configuration Guide that shipped with your Cisco 7200 series router, and as an addendum to the
Configuration Fundamentals Configuration Guide.
The following sections are included in the publication:
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Copyright © 1996
Cisco Systems, Inc.
All rights reserved.
General Documentation Information, page 2
Cisco 7200 Series Overview, page 3
Port Adapters, page 6
— PA-4T Synchronous Serial Port Adapter, page 6
— PA-H and PA-2H High-Speed Serial (HSSI) Port Adapters, page 9
Agency Approvals for the Cisco 7200 Series Routers, page 13
Translated Safety Warnings, page 14
Cisco Connection Online, page 37
1

Advertisement

Table of Contents
loading

Summary of Contents for Cisco CISCO7206

  • Page 1 Cisco 7200 series router. Use the information in this publication in conjunction with the Cisco 72xx Installation and Configuration Guide that shipped with your Cisco 7200 series router, and as an addendum to the Configuration Fundamentals Configuration Guide.
  • Page 2: General Documentation Information

    • For systems with Cisco IOS Release 11.1(6), a Cisco-approved Release 11.1(6) beta software version, or a later Cisco IOS release, refer to the following modular configuration and modular command reference publications, as appropriate for your configuration: — Configuration Fundamentals Configuration Guide —...
  • Page 3: Cisco 7200 Series Overview

    Port adapters can be placed in any available port adapter slot, in any desired combination. The front of the Cisco 7200 series routers provides access to an Input/Output (I/O) controller and up to four or six network interface port adapters. The I/O controller has a local console port for connecting a data terminal (or data terminal equipment [DTE]) and an auxiliary port for connecting a modem (or other data communications equipment [DCE]) or other devices for configuring and...
  • Page 4 1 and continuing through port adapter slot 4 for the Cisco 7204, and slot 6 for the Cisco 7206. Port adapter slot 0 is the Fast Ethernet port on the I/O controller. Figure 3 shows the port adapter slot numbering for the Cisco 7206.
  • Page 5 DC-input power supply; a second 280W AC-input or DC-input power supply is available for the router. Figure 4 shows the rear of a Cisco 7200 series router that is configured with a single 280W AC-input power supply. (A power supply filler plate is installed over the second power supply bay.) Three internal fans draw cooling air into the chassis interior and across internal components to maintain an acceptable operating temperature (refer to Figure 4).
  • Page 6: Port Adapters

    Cisco 7204 and Cisco 7206 routers. PA-4T Synchronous Serial Port Adapter The Cisco Systems 4T port adapter (Part Number 73-1185) is used in Cisco 7200 series routers and is supplied by Cisco Systems Europe. The 4T port adapter provides the hardware necessary to connect Cisco 7200 series routers to digital leased line circuits (point to point) and to Packet Switched Public Data Networks (PSPDN).
  • Page 7 Always disconnect the host product chassis from any analogue telephone circuits or ISDN (where applicable) before removing any covers. If you have any doubt as to how to safely install the 4T port adapter correctly in a Cisco 7200 series router, please seek advice from a qualified telecommunications engineer.
  • Page 8 Port Adapters Installation Requirements This section describes special installation requirements for the 4T port adapter. Where applicable, the 4T port adapter is approved only for installation in a host and with host attachments, which are either type approved for such apparatus or covered by a General Approval. Except at the edge connector, which plugs into the router’s midplane, clearance and creepage distances of X millimeters (mm) and Y mm, as listed in Table 1, must be maintained between the 4T port adapter and other parts of the host, including any other port adapters.
  • Page 9: Pa-H And Pa-2H High-Speed Serial (Hssi) Port Adapters

    The HSSI port adapters provide up to two high-speed serial interfaces; PA-H provides a single network interface, and PA-2H provides two interfaces. Wide-area network (WAN) operating software for the HSSI port adapters is bundled with the Cisco IOS software image that is running on the Cisco 7200 series router.
  • Page 10 Always disconnect the host product chassis from any analogue telephone circuits or ISDN (where applicable) before removing any covers. If you have any doubt as to how to safely install the HSSI port adapters correctly within a Cisco 7200 series router, please seek advice from a qualified telecommunications engineer.
  • Page 11 Port Adapters Installation Requirements This section describes special installation requirements for the HSSI port adapters. Where applicable, the HSSI port adapters are approved only for installation in a host and with host attachments, which are either type approved for such apparatus or covered by a General Approval. Except at the edge connector, which plugs into the router’s midplane, clearance and creepage distances of X millimeters (mm) and Y mm, as listed in Table 2, must be maintained between the HSSI port adapters and other parts of the host, including any other port adapters.
  • Page 12 SELV circuits should only be connected to other SELV circuits. Connection of power supply: the Cisco 7200 series routers are intended for use when supplied with AC power from a power source providing 5A maximum at 110 VAC and 2.5A maximum at 240 VAC, 50 through 60 Hz, with the chassis fully configured.
  • Page 13: Agency Approvals For The Cisco 7200 Series Routers

    Agency Approvals for the Cisco 7200 Series Routers Agency Approvals for the Cisco 7200 Series Routers The Cisco 7200 series routers have the following agency approvals: • Safety: UL 1950, CSA 22.2 No.950, EN60950, AUSTEL TS001, AS/NZS 3260, IEC 950 •...
  • Page 14: Translated Safety Warnings

    This section repeats in multiple languages the warnings in this publication. In addition, this section contains translated warnings that can be used with other documentation related to the Cisco 7200 series routers, such as the documents for the Cisco 7200 series field-replaceable units.
  • Page 15: Power Disconnection Warning

    Translated Safety Warnings Power Disconnection Warning Before working on a system that has an on/off switch, turn OFF the power and unplug the Warning power cord. Waarschuwing Voordat u aan een systeem werkt dat een aan/uit schakelaar heeft, dient u de stroomvoorziening UIT te schakelen en de stekker van het netsnoer uit het stopcontact te halen.
  • Page 16: Lightning Activity Warning

    Translated Safety Warnings Antes de abrir o chassis, desligue os cabos da rede telefónica para evitar contacto com a Aviso tensão da respectiva rede. Antes de abrir el chasis, desconectar el cableado dirigido a la red telefónica para ¡Advertencia! evitar contacto con voltajes de la propia red. Koppla loss ledningarna till telefonnätet innan du öppnar chassit så...
  • Page 17: Dc Power Supply Warning

    Translated Safety Warnings Ne pas toucher le bloc d'alimentation quand le cordon d'alimentation est branché. Avec Attention les systèmes munis d'un commutateur marche-arrêt, des tensions de ligne sont présentes dans l'alimentation quand le cordon est branché, même si le commutateur est à l'arrêt. Avec les systèmes sans commutateur marche-arrêt, l'alimentation est sous tension quand le cordon d'alimentation est branché.
  • Page 18: Dc Power Disconnection Warning

    Translated Safety Warnings Wenn Litzenverdrahtung erforderlich ist, sind zugelassene Verdrahtungsabschlüsse, z.B. Warnung für einen geschlossenen Regelkreis oder gabelförmig, mit nach oben gerichteten Kabelschuhen zu verwenden. Diese Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen. Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l’alto.
  • Page 19 Translated Safety Warnings Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC Avvertenza non sia alimentato. Per verificare che tutta l’alimentazione sia scollegata (OFF), individuare l’interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l’interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
  • Page 20 Translated Safety Warnings Depois de ligar o sistema de fornecimento de corrente contínua, retire a fita isoladora da Aviso manivela do disjuntor, e volte a ligar a corrente ao deslocar a manivela para a posição ON (Ligado). Después de cablear la fuente de alimentación de corriente continua, retirar la cinta ¡Advertencia! de la palanca del interruptor automático, y restablecer la alimentación cambiando la palanca a la posición de Encendido (ON).
  • Page 21: Installation Warning

    Translated Safety Warnings A figura mostra o bloco do terminal de fornecimento de corrente contínua. Ligue o Aviso fornecimento de corrente contínua utilizando as extremidades apropriadas no final do cabo, conforme ilustrado. A sequência correcta de instalação é terra-a-terra, positivo-positivo (linha para L), e negativo-negativo (neutro para N).
  • Page 22 Translated Safety Warnings Avant de travailler sur un châssis ou à proximité d'une alimentation électrique, Attention débrancher le cordon d'alimentation des unités en courant alternatif ; couper l'alimentation des unités en courant continu au niveau du disjoncteur. Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Warnung Wechselstromeinheiten das Netzkabel ab bzw.
  • Page 23 Translated Safety Warnings Dette produktet er avhengig av bygningens installasjoner av kortslutningsbeskyttelse Advarsel (overstrøm). Kontroller at det brukes en sikring eller strømbryter som ikke er større enn 120 VAC, 15 A (USA) (240 VAC, 10 A internasjonalt) på faselederne (alle strømførende ledere). Este produto depende das instalações existentes para protecção contra curto-circuito Aviso (sobrecarga).
  • Page 24 Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing To prevent bodily injury when mounting or servicing this unit in a rack, you must take Warning special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: —...
  • Page 25 Translated Safety Warnings Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in Avvertenza un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale: —...
  • Page 26: Overtemperature Warning

    Translated Safety Warnings Overtemperature Warning To prevent the switch from overheating, do not operate it in an area that exceeds the Warning maximum recommended ambient temperature of 104F (40C). To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings. Om oververhitting van de schakelaar te voorkomen, mag u die niet bedienen in een Waarschuwing ruimte die de maximale aanbevolen omgevingstemperatuur van 104 F (40 C) overschrijdt.
  • Page 27: Invisible Laser Radiation Warning

    Translated Safety Warnings Invisible Laser Radiation Warning Invisible laser radiation may be emitted from the aperture ports of the single-mode FDDI Warning card when no cable is connected. Avoid exposure and do not stare into open apertures. Following is an example of the warning label that appears on the product: CLASS 1 LASER PRODUCT LASERPRODUKT DER KLASSE 1 PRODUIT LASER DE CLASSE 1...
  • Page 28: Tn Power Warning

    Translated Safety Warnings TN Power Warning The device is designed to work with TN power systems. Warning Het apparaat is ontworpen om te functioneren met TN energiesystemen. Waarschuwing Koje on suunniteltu toimimaan TN-sähkövoimajärjestelmien yhteydessä. Varoitus Ce dispositif a été conçu pour fonctionner avec des systèmes d'alimentation TN. Attention Das Gerät ist für die Verwendung mit TN-Stromsystemen ausgelegt.
  • Page 29 Translated Safety Warnings As portas "Ethernet", "10BaseT", "Token Ring", "Console", and "AUX" são circuitos de Aviso segurança de baixa tensão (SELV). Estes circuitos deverão ser apenas ligados a outros circuitos SELV. Devido ao facto de os circuitos BRI (Interface de Ritmo Básico) serem tratados como sendo de tensão equivalente à...
  • Page 30: Warning Statement For Norway And Sweden

    Translated Safety Warnings Il collegamento ISDN (Integrated Services Digital Network -Rete digitale a servizi Avvertenza integrati) viene considerato come una fonte di tensione che dovrebbe essere inaccessibile al contatto dell’utente. Gli utenti non devono manomettere o provare ad aprire le apparecchiature o i componenti di collegamento forniti dalla società...
  • Page 31: Battery Handling Warning

    Translated Safety Warnings Battery Handling Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery Warning only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt.
  • Page 32: Product Disposal Warning

    Translated Safety Warnings Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk. Advarsel Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à Aviso terra durante a sua utilização normal. Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté ¡Advertencia! conectado a tierra durante el uso normal.
  • Page 33: Jewelry Removal Warning

    Translated Safety Warnings Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist. Advarsel Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última Aviso a ser desligada. Al instalar el equipo, conectar la tierra la primera y desconectarla la última. ¡Advertencia! Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
  • Page 34 Translated Safety Warnings Lifting the Chassis by the Handles Warning Never attempt to lift the chassis with the handles on the power supplies or the switching Warning modules. These handles are not designed to support the weight of the chassis. Using them to lift or support the chassis can result in severe damage to the equipment and serious bodily injury.
  • Page 35 Das Wechselstrom-Netzgerät für den Cisco 7204 und Cisco 7206 ist mit Warnung zweipoliger/neutraler Sicherung ausgestattet. L’alimentatore CA per il Cisco 7204 ed il Cisco Cisco 7206 èdotato di fusibili a polo Avvertenza doppio/neutro. Advarsel Vekselstrømsforsyningsenheten for Cisco 7204 og Cisco 7206 har både topolede og nøytrale sikringer.
  • Page 36 Translated Safety Warnings Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med Advarsel begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
  • Page 37: Cisco Connection Online

    SwitchWare, SynchroniCD, The Cell, The FastPacket Company, TokenSwitch, TrafficDirector, Virtual EtherSwitch, VirtualStream, VlanDirector, Web Clusters, WNIC, Workgroup Director, Workgroup Stack, and XCI are trademarks; Access by Cisco, Bringing the Power of Internetworking to Everyone, Enter the Net with MultiNet, and The Network Works.
  • Page 38 Cisco Connection Online...

This manual is also suitable for:

Cisco7204Cisco7206-dcCisco7204-dc

Table of Contents