Desa CRL3124PA/NA Owner's Operation And Installation Manual page 22

Unvented (vent-gree) gas log heater
Table of Contents

Advertisement

5. Turn control knob counterclockwise
to the PILOT position. Press in
control knob for five (5) seconds (see
Figure 31).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burn-
ers should light. Set control knob to any
heat level between HI and LO.
9. Turn control knob clockwise
PILOT position to shut off burner leaving
pilot lit.
Ignitor Button
Figure 31 - Control Knob and Ignitor
Button Location
22
OPERATION
THERMOSTAT-CONTROLLED MODELS
Control Knob
www.desatech.com
Continued
Ignitor
Electrode
Thermocouple
1. Turn control knob clockwise
OFF position.
2. Close equipment shutoff valve (see Figure
16, page 15).
CONTROL OPERATION
The thermostat control knob can be set to any
comfort level between HI and LO. The ther-
mostat will gradually modulate the heat output
and flame height from higher to lower settings
or pilot, in order to maintain the comfort level
you select. The ideal comfort setting will vary
by household depending upon the amount of
space to be heated, the output of the central
heating system, etc.
Note: Selecting the HI setting with the control
knob will cause the burners to remain fully on,
without modulating down in most cases.
1. Follow steps 1 through 5 under Lighting
to the
Instructions, page 21.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8,
under Lighting Instructions, column 1.
Pilot Burner
Figure 32 - Pilot
TO TURN OFF GAS
TO APPLIANCE
THERMOSTAT
MANUAL LIGHTING
PROCEDURE
to the
113097-01L

Advertisement

Table of Contents
loading