5. Slightly press and turn control knob coun-
terclockwise
Press in control knob for five (5) seconds
(see Figure 29).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. If control knob does not pop out
when released, contact a qualified service
person or gas supplier for repairs.
8. Slightly depress and turn control knob
counterclockwise
ing level. The burner(s) should light. Set
control knob to any heat level between HI
and LO.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise
HI position then press in and turn clock-
wise
to PILOT position.
WARNING: Do not operate
heater between PILOT and HI
positions.
Ignitor Button
Figure 29 - Control Knob and Ignitor
Button Location
20
OPERATION
MANUALLy-CONTROLLED MODELS
to the PILOT position.
to desired heat-
Control Knob
www.desatech.com
Continued
Ignitor
Electrode
Thermocouple
VARIABLE CONTROL
The variable control valve can be set to any
heat setting and flame height desired, by sim-
ply turning the control knob until that setting
is attained. Even the lowest setting provides
realistic, dancing yellow flames. Selecting
higher settings produces greater heat output.
This results in increased heating comfort.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
1. Press in and turn control knob clockwise
2. Turn control knob clockwise
pilot position.
3. Press in control knob and turn clockwise
4. Close equipment shutoff valve (see Figure
to the
16, page 15).
1. Follow steps 1 through 5 under Lighting
Instructions, pages 19 and 20.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8,
under Lighting Instructions, column 1.
Pilot Burner
Figure 30 - Pilot
OPERATION
TO TURN OFF GAS
TO APPLIANCE
to the HI position.
to the OFF position.
MANUAL LIGHTING
PROCEDURE
to the
113097-01L