SaFETy INFORMaTION
Continued
6. Turn fireplace off and let cool before servicing,
installing or repairing. Only a qualified service
person should install, service or repair this
fireplace. Have fireplace inspected annually
by a qualified service person.
7. You must keep control compartments, burn-
ers and circulating air passages clean. More
frequent cleaning may be needed due to ex-
cessive lint and dust from carpeting, bedding
material, etc. Turn off the gas valve and pilot
light before cleaning fireplace.
8. Have venting system inspected annually by a
qualified service person. If needed, have vent-
ing system cleaned or repaired. See Cleaning
and Maintenance, page 28.
9. Do not use this fireplace to cook food or burn
paper or other objects.
10. This appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1.
11. Do not use fireplace if any part has been under
water. Immediately call a qualified service per-
son to arrange for replacement of the unit.
12. Do not operate fireplace if log is broken.
13. Provide adequate clearances around air openings.
pRODUCT
IDENTIFICaTION
Upper Louver Panel
Nailing
Flange
Glowing
Embers
Lower
Louver
Panel
Electronic
Control Valve
Burner Assembly
Switch Bracket for Optional
Remote and Blower
Figure 1 - Direct-Vent Fireplace with
Electronic Ignition
4
Glass Door Assembly
Flue Collar
Log
Set
Lava
Rock
www.desatech.com

lOCal CODES

Install and use fireplace with care. Follow all local
codes. In the absence to local codes, use the cur-
rent National Fuel Gas Code ANSI Z223.1/NFPA
54* (USA) or the current CSA-B149.1 Installation
Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269

pRODUCT FEaTURES

These are a few facts that can help you understand
and enjoy your direct-vent fireplace:
• The venting system may be routed to the out-
side of your home in several ways. It may vent
through the roof (vertical) or it may vent to an
outside/exterior wall (horizontal). The vent
pipe installation is very important to allow for
proper operation. You must follow the venting
instructions very carefully for either vertical or
horizontal applications.
• This fireplace may be installed in any room of
your house provided all local codes and these
installation instructions are followed.
• The blower requires electricity if installed. If
you plan to install the blower at a later date,
outlet must be wired at the bottom of the fire-
place when framing.
• The electronic ignition creates spark to ignite
the pilot light. It does not require any matches,
batteries or any other sources of ignition to light
the pilot.
• Each time you turn on your fireplace, you may
notice some amount of condensation on the in-
side of the fireplace glass. This is normal and will
disappear after 10-20 minutes of operation.
• Your direct-vent gas fireplace system (fireplace
and venting) is a balanced and sealed gas op-
erating unit. It requires approximately 10-20
minutes of operating time before the flame
pattern stabilizes.
116647-01B