FIREplaCE
INSTallaTION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas fireplace or opening main gas
valve located on or near gas meter for natural
gas fireplace or using compressed air.
3. Check all joints from propane/LP supply tank
for propane/LP or gas meter for natural gas to
equipment shutoff valve (see Figure 34 or Figure
35). Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct
all leaks at once.
Equipment
Shutoff
Valve
Figure 33 - Equipment Shutoff Valve
Equipment
Shutoff Valve
Propane/LP
Supply Tank
Figure 34 - Checking Gas Joints for
Propane/LP Gas Fireplace
Equipment
Shutoff
Valve
Gas
Meter
Figure 35 - Checking Gas Joints for
Natural Gas Fireplace

Open
Closed
Gas Valve
Gas Valve
www.desatech.com
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 33).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural gas
fireplace.
3. Make sure control knob of fireplace is in the
OFF position.
4. Check all joints from equipment shutoff valve
to gas valve (see Figure 34 or Figure 35).
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct
all leaks at once.
5. Light fireplace (see Operating Fireplace, page
23). Check all other internal joints for leaks.
6. Turn off fireplace (see To Turn Off Gas to Appli-
ance, page 24).
REMOVING/REPLACING GLASS
DOOR
CAUTION: Do not operate
this fireplace with a broken glass
door panel or without the glass
door panel securely in place.
For replacement part informa-
tion see Replacement Parts,
page 32.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not re-
move if glass is hot. Keep children
and pets away from glass.
WARNING: If fireplace has
been running, turn off and un-
plug fireplace. Let cool before re-
moving glass door or louvers.
Removing Louver Panels
Remove the top and bottom louver panels by si-
multaneously pulling both top end spring latches
towards the center of the appliance until they are
disengaged from the locating holes (see Figure 36,
page 23). Repeat for bottom spring latches and pull
the louvers outward. To install or replace items
removed, simply reverse the procedures above.