Detaching The Fluidfs Nas Cluster Solution Controller; Removing And Replacing The Nas Cluster Solution Controller; Attaching The Nas Cluster Solution Controller - Dell PowerVault NX3600 Administrator's Manual

Fluidfs nas solutions
Hide thumbs Also See for PowerVault NX3600:
Table of Contents

Advertisement

Detaching The FluidFS NAS Cluster Solution Controller

In order to bring the cluster into the journalling mode you need to detach a controller while any hardware is being
replaced. This ensures that the system can be brought back to service with no downtime.
You may have to detach the controller under the following circumstances:
A controller needs to be replaced with a new standby controller.
The administrator wants to attach a working controller to another (more critical) cluster.
Detaching A Controller Using The NAS Manager
1.
Select Cluster Management → Hardware → Controllers Management.
The Controllers Management page is displayed.
2.
From the list of available controllers, select the appropriate controller and click Detach.
The selected controller is detached from the cluster, and powered off. This operation takes around 10 to 15
minutes.

Removing And Replacing The NAS Cluster Solution Controller

To remove and replace the NAS cluster solution controller:
1.
Label all the cables correctly before disconnecting any cables.
2.
Disconnect all cables from the back of the controller.
3.
Remove the failed controller from the appliance chassis.
4.
Install the new controller in the appliance chassis.
5.
Connect all cables to the new controller.
NOTE: For more information on removing and installing the controller, see the
Manual , at support.dell.com/manuals.
6.
Ensure that the cables are reconnected to the same ports when installing the controller.
7.
Power ON the new system by inserting the power cable.

Attaching The NAS Cluster Solution Controller

Before completing this procedure, verify that the controller being attached is in standby mode and powered up. You can
verify that the controller is ON and in standby mode, if the power LED of the new controller is flashing green at around 2
flashes per second.
Attaching A Controller Using The NAS Manager
1.
Select Cluster Management → Hardware → Controllers Management.
The Controllers Management page is displayed.
2.
From the list of available controllers, select the appropriate controller and click Attach.
NOTE: The following are additional steps required for the Dell Compellent FS8600 NAS Solutions.
NOTE: Fabric zoning must be updated manually on the fibre optic switch.
3.
After the attach operation completes, the NAS Manager displays the WWN's for the newly attached controller, for
fibre channel switch zoning.
108
Dell FluidFS NAS Solution Owner's

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault nx3610