Routehelp; Topologyshow - Dell PowerVault 50F Installation And Troubleshooting Manual

Dell powervault 51f 8-port fibre channel switch installation and troubleshooting guide
Hide thumbs Also See for PowerVault 50F:
Table of Contents

Advertisement

4-40 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
Table 4-23. nbrStateShow Command Field Descriptions (continued)
Field
Description
Remote Port
Corresponds to remPort in the neighbor data structure.
State
The neighbor's current state. Its value must be NB_ST_FULL
for the ISL to forward frames to the adjacent switch. Other
values may be transitory, however if a value is retained for
more than ten seconds, contact Dell for technical
assistance.

routeHelp

The following example shows the routeHelp command screen, which displays the
routing help commands.
switch:admin> routeHelp
bcastShow
fspfShow
interfaceShow
iodReset
iodSet
LSDbShow
mcastShow
nbrStateShow

topologyShow

uRouteConfig
uRouteRemove
uRouteShow
topologyShow
The topologyShow command displays all paths to a domain including:
Output port(s) used to route frames to the domain
The routing cost to reach the domain
The input ports routed through the output port
The FSPF protocol supports equal cost multipaths, so there could be multiple parallel
paths between two switches.
The command syntax is
The command syntax is
domain.
Print broadcast tree information
Print FSPF global information
Print FSPF interface information
Turns off the in-order delivery option
Turns on the in-order delivery option
Print Link State Database entry
Print multicast tree information
Print neighbor's summary information
Print paths to domain(s)
Configure static unicast route
Remove static unicast route.
Print port's unicast routing info
topologyShow
to list all domains.
topologyShow < domain ID >
to list the specified

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault 51fPowervault 56f

Table of Contents