PRE-INSTALLATION PREPARATION
8
Framing
Installing Transition Pipe and Starter Collar
PRE-INSTALLATION
PREPARATION
Continued
FRAMING
1. Frame appliance enclosure as illustrated in Figures 7 and 8.
Note: If a wall covering is used to line the enclosure, then all
measurements must be from the surface of the covering.
2. Place the appliance into the framing and secure it.
Note: If appliance is to be raised above floor level, a platform
must be built to support the appliance.
3. Install the supply line to the appliance using a 1/2" NPT black
iron gas line terminating 2
ance. The gas line must be installed through the lower left side
access point or alternate access hole in the bottom of the appli-
ance (see Figure 19, page 12).
4. Repack insulation around the gas line to cover any remaining
openings in the conduit sleeve. Prepare the incoming gas line
with teflon tape or pipe joint compound and hook-up incoming
gas line to the flexible gas line.
Note: If 1/2" NPT black iron pipe does not mate with fitting at
the end of flexible gas line, remove fitting and replace with a 37
degree flare 3/4"-12, 1/2" NPT (female) fitting.
WARNING: When finishing appliance, do not
overlap combustible material onto the black front
face. Brick, tile, or other noncombustible materials
may be applied to the face provided that any gap is
between the material used and the face is caulked
with a noncombustible caulking.
B
C
M36(B,H)/VM36(B,H) M42(B,H)/VM42(B,H)
A
40
3
/
" (1020mm)
8
3
B
21
/
" (543mm)
8
1
C
41
/
" (1048mm)
4
Figure 7 - Rough Opening for Installing in Wall
5
/
" above the bottom of the appli-
16
A
44
3
/
" (1121mm)
8
1
23
/
" (587mm)
8
1
48
/
" (1226mm)
4
For more information, visit www.desatech.com
For more information, visit www.desatech.com
These Dimensions Allow for a 3/4"
Clearance at Sides and Back of
Fireplace. However, 0" Clearance
is Permitted
D
C
B
M36(B,H)/VM36(B,H)
A
24
1
/
"(622.3mm)
2
7
B
73
/
"(1876.4mm)
8
3
C
52
/
"(1326mm)
16
D
17
1
/
"(438.2mm)
4
Figure 8 - Corner Installation Guidelines
INSTALLING TRANSITION PIPE AND
STARTER COLLAR
The transition pipe and starter collar shown in Figure 9 are supplied
with the fireplace, unattached and ready for installation. Remove the
starter collar and set aside. Slide the transition pipe over the vent
collar and attach with a minimum of three screws. Replace the
starter collar over the transition pipe and attach using four screws
located on the leg stands (five used on the model M42). To install
B-vent piping, slide the first piece of B-vent over the transition pipe
and attach with a minimum of two screws.
Figure 9 - Installing Transition Pipe and Starter Collar
3/4" Clearance
A
Not Required
at Nailing
Flanges
M42(B,H)/VM42(B,H)
27
9
/
"(700.1mm)
16
7
83
/
"(2130.4mm)
8
5
59
/
"(1506.6mm)
16
19
1
/
"(495.3mm)
2
B-Vent Piping
Starter Collar
Transition Pipe
Vent Collar
108795-01K