Connecting LAMP Contact

The HCD544 camera is equipped with LAMP and GND
external contact terminals. When the LAMP terminal is
connected to the GND terminal, the camera is forced into
night mode (see page 15). It stays in night mode until the
LAMP terminal is disconnected from the GND terminal.
Figure 4

Adjusting The Back Focus

To adjust the back focus, aim the camera towards a darker
area, or use a Neutral Density lens filter. For best results,
there should be a minimum of 15 ft (4.5 m) between the
camera and the target focal area.
1.
Loosen the setscrews with a Phillips screwdriver.
2.
Set the Zoom lens adjustment to Wide and the Focus
lens adjustment to Near.
3.
Adjust the back focus ring to focus the picture.
4.
Retighten the setscrews.
Document 800-01954 Rev A
08/08
LAMP and GND Terminals
GND terminal
LAMP terminal