Setting the Baud Rate and Video Format
The baud rate and video format are set using the 4-position DIP switch.
Use the following tables as a reference:
Baud Rate
1
9600 bps
OFF
4800 bps
ON
2400 bps
OFF
1200 bps
ON
Video Format
3
CVI
OFF
TVI
OFF
AHD
ON
SD
ON

Connecting the Cables

Power
RS485
Video
Out
Audio
Alarm
Red
Power
Black
Yellow & Green
Yellow
RS485
Orange
Video Out
BNC
White
Audio
Black
Blue
Green
Alarm
Red
Brown
Yellow & Green
Recommended Cables and Maximum Distances
Type
Recommended Cable
Power
18 AWG 2-conductor
Data
Cat5 24 AWG twisted pair (use
shielding in high electrical
interference locations)
Video
RG-59/U coaxial cable with BNC
crimp, 75 ohm, copper conductor
Alarm
Belden 8205
RS-485 Connection Guidelines
Data termination (120 ohm) is set at the rear of the camera, next to
the DIP switches. It is open by default, with the jumper over pins 2 and
3. To terminate the camera, place the jumper over pins 1 and 2 (see
figure at right).
In an RS485 bus, terminate the two endpoints to prevent signal reflection. If a
star topology is used, terminate all connected PTZ cameras and use an RS485
data distributor (such as HDCD8TP).
Note: For more information, please refer to the HDZP30XD4 user guide (800-23522). The
guide is available for download from www.honeywellvideo.com.
© 2017 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written permission from Honeywell. The information in this publication is believed to be accurate in all respects.
However, Honeywell cannot assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change without notice. Revisions or new editions to this publication may be issued to
incorporate such changes. For patent information, see www.honeywell.com/patents.
2
OFF
OFF
ON
ON
4
OFF
ON
OFF
ON
24 V AC
24 V AC
Earth
A+
B-
Audio IN
Audio GND
Alarm OUT 1
Alarm COM1
Alarm IN1
Alarm IN2
Alarm GND
Maximum Distance
153 ft (46.5 m)
5905 ft (1800 m) @ 2400 bps
3937 ft (1200 m) @ 4800 bps
2625 ft (800 m) @ 9600 bps
750 ft (229 m)
10,000 ft (3048 m)
1 2 3

Mounting the Camera

The wall mount weighs 1.08 lb (0.49 kg) and can be installed directly to a load-bearing
wall, or to a corner or pole using an appropriate adapter.
Important!
Ensure that the mounting surface can support at least three times the
combined weight of the camera and mount (at least 27.72 lb/12.57 kg).
8
7
1/3
5
2
4
6
Configuring the OSD Menu Settings
When the camera is connected to a Honeywell Performance Series DVR (HRHQXXXX/
HRHTXXXX), you can access and configure the camera's on-screen display (OSD) menu
using either the HQA or RS485 control modes.
OSD Configuration: Up-the-Coax
Note: The DVR's PTZ control mode and protocol must be set to HQA (in Main Menu >
Setting > System > PTZ) for up-the-coax control of the OSD menu.
1.
Verify that the camera is connected to a Honeywell Performance Series DVR.
2.
Turn on the DVR, right-click to display the shortcut
menu, then click Camera Menu.
Log on to the DVR as the admin user. The Menu
3.
Operation window opens.
Click Enter to display the camera's OSD menu.
4.
5.
To configure OSD settings, in the Menu Operation
window, click the up or down arrows to move through
the menu list, click the left or right arrows to change
a setting, or click Enter to enter a submenu (
6.
After you have finished configuring the camera, scroll down to Exit, and then click
Enter to exit the OSD menu. Right-click to close the Menu Operation window.
OSD Configuration: RS485
Note: The DVR's PTZ control mode must be set to Serial (in Main Menu > Setting >
System > PTZ) for RS485 control of the OSD menu.
Task
Action
To display the OSD menu
Call Preset 95.
To scroll through the OSD menu
Move the joystick up or down.
To change a setting
Move the joystick left or right.
Press Iris + (Iris Open).
To open a submenu (
) or
execute a command
To exit the OSD menu
Press Iris – (Iris Close).
www.honeywell.com/security
+1 800 323 4576 (North America only)
https://www.honeywellsystems.com/ss/techsupp/index.html
Document 800-23323 – Rev A – 08/2017
1.
Loosen the mount locking
screw.
2.
Screw the adapter to the
mount.
3.
Tighten the mount locking
screw.
4.
Loosen the three locking
screws on the adapter.
5.
Feed the camera cables
through the mount.
6.
Attach the camera body to the
adapter and tighten the three
locking screws to secure the
camera body to the mount.
7.
Make connections of the
camera cables with the cables
fed through the wall.
8.
Attach the mount to the wall
using appropriate hardware.
Finished