MANTEL CLEARANCES

In addition to meeting noncombustible ma-
terial clearances, you must also meet
required clearances between fireplace open-
ings and mantel shelf on each side of the
fireplace. If you do not meet the clearances
listed below, you will need a hood.
Determining Minimum Mantel
Clearance
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Determining Minimum Mantel
Clearance When Using a Hood
If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level,
you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).
B. If combustible materials are less than
14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).
104674
Minimum Non-
Combustible
Material
Figure 6 - Minimum Mantel Clearances Without Using Hood
12"
10"
8"
6"
2
Minimum Non-
Combustible
Material
Hood
Hood (GA6050,
(GA6050, GA6052)
GA6052 or GA6053)
Figure 7 - Minimum Mantel Clearances When Using Hood
14"
14"
Min.
Min.
Non-Combustible Mate
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
9
OWNER'S MANUAL
Mantel Shelf
10"
8"
6"
1 /2
2
"
(A)
12"
18"
20"
Minimum Non-
Distances to
Combustible
Underside of
Material Height
Mantel
Mantel Shelf
1 /2
"
8"
12"
15"
Min.
Distances to
Underside of
Mantel
Combustible
Combustible
Material
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Underside of
Mantel Shelf
All minimum
distances are
in inches
22"
24"
Top of Fireplace
Opening
Underside of
Mantel Shelf
All minimum
distances are
in inches
18"
20"
Top of Fireplace
Opening
Hearth
Hearth
Combustible
Com
Material
Mat
5"
5"
Min.
Min.
Continued