Mantel Clearances - Desa CCL3924NR Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

If Using Mantel
You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.)
must be at least 1/2" thick. With sheet metal,
you must have noncombustible material be-
hind it. Noncombustible material must extend
at least 8" up. If noncombustible material is
less than 12", you must install the fireplace
hood accessory. Even if noncombustible
material is more than 12", you may need the
hood accessory to deflect heat away from
your mantel shelf. See Figure 5, 6 and 7 for
minimum clearances.
IMPORTANT: If you cannot meet these mini-
mum clearances, you must operate heater
with chimney flue damper open. Go to Install-
ing Damper Clamp Accessory for Vented
Operation, page 12.
Noncombus-
Requirements for Safe
tible Material
Installation
Distance (A)
12" or more
Noncombustible material
okay.
B e t w e e n 8 "
Install fireplace hood acces-
and 12"
sory (GA6050, GA6052 or
GA6053 see Accessories,
page 34).
Less than 8"
Noncombustible material
must be extended to at
least 8". See Between 8"
and 12", above. If you can-
not extend material, you
must operate heater with
flue damper open.
Heat Resistant
Material
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
111161-01K
INSTALLATION
Continued
Minimum
Noncombustible
Material
Figure 6 - Minimum Mantel Clearances
Minimum
Noncombustible
Material
Figure 7 - Minimum Mantel Clearances

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
(A)
clearances between fireplace opening and
mantel shelf. If you do not meet the clearances
listed below, you will need a hood.
Determining Minimum Mantel Clearances
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
www.desatech.com
Mantel Shelf
10"
8"
6"
1 /2
2
"
(A)
12"
18"
20"
Minimum
Distances to
Noncombustible
Underside of
Material Height
Mantel
Without Using Hood
Mantel Shelf
12"
10"
8"
6"
2
1 /2
"
8"
12"
15"
Min.
Hood
Distances to
(GA6050,
Underside of
GA6052)
Mantel
When Using Hood
Underside
of Mantel
Shelf
All minimum
distances are
in inches
Log Set
22"
24"
All
Models
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
All minimum
distances are
in inches
Log Set
18", 24",
18"
20"
30" Models
All
Top of
Models
Fireplace
Opening
11