Checking Gas Connections - Vanguard VP11 Owner's Operation And Installation Manual

Vent-free propane gas heater
Table of Contents

Advertisement

CHECKING
GAS
CONNECTIONS
10
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping
and/or fittings.
3/8" NPT
Pipe Nipple
Manual
Shutoff
Valve *
From External
Regulator
(11" W.C. to 14" W.C.
Pressure)
3" Minimum
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See ACCESSORY, page 21.
Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.
Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.
Make sure external regulator has been installed between propane
supply and heater. See guidelines under CONNECTING TO GAS
SUPPLY, page 9.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
Figure 11 - Gas Connection
!
WARNING
WARNING ICON
G 001
!
WARNING
WARNING ICON
G 001
!
CAUTION
WARNING ICON
G 001
Pressure
Regulator
Heater
Cabinet
Ground Joint
Union
Tee Joint
Reducer
Test
Bushing to
Gauge
1/8" NPT
Connection *
1/8" NPT
Plug Tap
Tee
Joint
Sediment
Pipe
Trap
Nipple
Cap