Panasonic KV-S5055C Operating Manual page 83

High speed color scanner
Hide thumbs Also See for KV-S5055C:
Table of Contents

Advertisement

Symptom
Scanned image is skewed.
The scanned document is
blank.
Vertical lines appear on the
scanned document.
The scanning density is
uneven.
The color of the scanned
document is extremely
different from the original
document.
Dark spots or noise appear on
the scanned documents.
If you still experience problems after following these suggestions, please contact our Technical Support
Department at 1-800-726-2797 for further assistance. (U.S.A. only)
Possible Cause
The document guides are not
adjusted to the size of the document
to be scanned, or the document to be
scanned is set slanted on the hopper.
Right and left sides of the document
to be scanned are not the same in
height, because of curling or folding.
The document to be scanned was
loaded upside down.
The scanning glass is dirty.
The scanning glass is dirty.
The quantity distribution of light
varies.
The settings of the computer monitor
are wrong.
The scanning glass is dirty.
Remedy
Adjust the document guides properly
to the size of the document to be
scanned (page 22).
Flatten the document (page 19) and
load it again after reducing the pages.
Load the document correctly.
(page 22)
Clean the conveyor, self-cleaning
brushes, and the ion outlets (page 53),
and then clean the scanning glass (F
and B) (page 60).
Clean the scanning glass (F and B).
(page 60)
Adjust shading. (page 84)
Adjust the computer monitor settings.
Clean the conveyor, self-cleaning
brushes, and the ion outlets (page 53),
and then clean the scanning glass (F
and B) (page 60).