D20H, D30H AND D44H MODELS
PORTABLE FORCED AIR HEATERS
SERVICE
PROCEDURES
WARNING: Never service
heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.
UPPER SHELL REMOVAL
1.
Remove screws and lock washers along
each side of heater using 5/16" nut-
driver. These screws attach upper and
lower shells together.
2. Lift upper shell off.
3. Remove fan guard.
FUEL FILTER
(D20H Model)
1. Remove side cover screws using 5/16"
nut-driver.
2. Remove side cover.
3.
Pull rubber fuel line off fuel filter neck.
4. Carefully pry bushing and fuel filter out
of fuel tank.
5.
Wash fuel filter with clean fuel and re-
place in tank.
6. Attach rubber fuel line to fuel filter
neck.
7. Replace side cover.
FUEL FILTER
(D30H and D44H Models)
1. Remove side cover screws using 5/16"
nut-driver.
2. Remove side cover.
3. Pull upper fuel line off fuel filter neck.
4. Carefully pry bushing, lower fuel line,
and fuel filter out of fuel tank.
5.
Wash fuel filter with clean fuel and re-
place in tank.
6. Attach upper fuel line to fuel filter neck.
7. Replace side cover.
Upper Shell
Figure 7 - Upper Shell Removal, D20H
Model
Fuel Filter
Side Cover
Figure 9 - Fuel Filter Removal, D20H Model
Fuel Filter, Bushing,
and Lower Fuel Line
Side Cover
Figure 10 - Fuel Filter Removal, D30H and D44H Models
8
Upper
Shell
Fan
Guard
Figure 8 - Upper Shell Removal, D30H
and D44H Models
Fuel Line
Fan
Guard
Upper Fuel
Line
105843