There are a total of 7 halogen light bulbs (type
GX6.35 rated 120 volts, 35 watts) in your unit.
• 2 bulbs provide illumination for the ember bed
beneath the log set
• 2 bulbs provide illumination for the flame
generation assembly
• 1 bulb provides illumination for the top con-
trasting light
• 2 bulbs for replacement
Most halogen light bulbs are rated to last approxi-
mately 1800 hours. Like all light bulbs, halogen
bulbs require periodic replacement. When the
bulbs in your unit have burned out you will notice
or more of the following:
• Contrasting light is dark
• Flame is dim or dark in certain areas
• Log set ember bed appears dim or dark in
certain areas
WARNING: Do not install
replacement bulbs that exceed
specified maximum watts.
Your unit must be opened in order to replace the light
bulbs. To reduce the number of times you need to
open the unit, replace all bulbs at the same time.
Removing Front of Unit
1. Unplug unit from the power supply.
2. Remove the four screws in front of the unit that
secure the grill to the main frame (see Figure 4).
3. Four clips hold the front panel to the frame of
the unit. Lift the front panel upwards until the
clips disconnect. Remove and place face up on
the floor.
Figure 4 - Stove Front Panel Removal
117191-01A
Figure 5 - Replacing Top Contrasting
www.desatech.com
Bulb