Row - Lexicon PCM 91 - REV 1 User Manual

Digital reverberator
Table of Contents

Advertisement

Basic Operation
PATCHING
(continued)
Assigning a Destination
(continued)
When Immediate is selected, the initial value of the parameter
value will correspond to the controller position. When Delayed is
selected, the stored value of the parameter will continue to be in
effect until the controller is moved. (It is, therefore, a good idea to
set a sensible value to the parameter in the Edit matrix.)
Mod Row Parameters that Can Be Assigned as Patch
Destinations
LFO1
Rate, Shape, P Width, Depth
LFO2
Rate, Shape, P Width, Depth
AR ENV
Attack, Release, Mode
Env L
Release
Env R
Release
Sw 1
Rate, P Width, Mode
Sw 2
Rate, P Width, Mode
Delay
Delay Time
Assigning Values
Once you have assigned a Destination, press Load /✱ to get to the
Values display at the top of the next column.
This display allows you to assign Destination values to specific
Source values. These assignments are made in pairs, each with a
value for the Source and a value for the Destination. For example,
the default is two pairs mapped as follows:
minimum Src value (0) = minimum Dst value
maximum Src value (127) = maximum Dst value
2-32
Src values are shown here. The asterisk
(✱) indicates that this field is available for
control with the ADJUST knob (and that
additional parameters are available by
pressing Load/✱).
This establishes a linear relationship between the parameter and
the controller. Inverse control is accomplished easily by reversing
these settings. As many as eight pairs of Destination/Source values,
or pivot points, can be assigned here, providing an exciting new
level of dynamic control.
Jump
When creating patches, there are situations in which you will want
to leave the Patch row to adjust parameters. To make this
convenient, a Jump command is available. Jumping is dependent
on the current Patch display, and is activated simply by pressing
Edit while a certain display is active. This will jump you out of the
Patch row and to the location where you can make the necessary
adjustments. Pressing Edit again will jump you back to the Patch
Row. (Note that using any front panel controls other than those
required to adjust the parameter to which you have jumped, will
disable the jump. This is not catastrophic, but it will require you to
return by using Up and Down and SELECT.)
The following Jumps are available:
Lexicon
The current Dst value is displayed here.
When you press Load/ ✱ again, the
asterisk will move to indicate that this
value is available to be changed by
turning ADJUST.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Pcm 91

Table of Contents