Installation Notes - Lexicon PCM 91 - REV 1 User Manual

Digital reverberator
Table of Contents

Advertisement

PCM 91

INSTALLATION NOTES

MOUNTING
The PCM 91 uses one EIA-standard rack space, and can be mount-
ed on any level surface or in a standard 19 inch (483 mm) rack. If
the PCM 91 is mounted in a rack or road case, support the rear of
the chassis to prevent possible damage from mechanical shock and
vibration.
The maximum ambient operating temperature is 104°F (40°C).
Provide adequate ventilation if the PCM 91 is mounted in a closed
rack with heat-producing equipment such as power amplifiers.
POWER REQUIREMENTS
The PCM 91 is equipped with a 3-pin IEC power connector and
detachable cord.
The PCM 91 will operate with power sources from 100 to 240 volts
AC, 50-60Hz. Power switching to actual line voltage is automatic.
AUDIO CONNECTIONS
Analog Audio
For best performance, maintain balanced connections, and use
high-quality, low-capacitance, twisted-shielded pair cable.
When connecting to single-ended, unbalanced devices, connect
the low side to signal ground at the unbalanced piece of
equipment. Output level does not change when connected to an
unbalanced input.
Mono Applications
Use a Y-connector inserted at the analog inputs and outputs to
have the signal summed to mono.
Note:
Be careful to keep input and output to all channels
wired consistently. Out-of-phase wiring can produce
audible effects.
Digital Audio
S/PDIF (CP-340 Type II) Consumer Digital Audio I/O. 75Ω coaxial
cable suited for digital audio or video signals is required. Audio
grade cable is not suitable. AES/EBU connections require balanced
connections using high quality, low capacitance, controlled
impedance, data communication, twisted-shielded pair cable.
Microphone cable may introduce a significant amount of jitter
into the signal, causing distortion.
CONTROL CONNECTIONS
Dual Footswitch/Foot Controller
One 1/4 inch T/R/S phone jack is provided for 2 momentary
footswitches. Another 1/4 inch T/R/S phone jack is provided for a
footpedal (minimum 100Ω to maximum 10kΩ
Normally open or normally closed momentary switches are
suitable. At power on, the PCM 91 assumes the switch is off. Use
shielded, twisted-pair cable with shield connected to sleeve. See
diagram on page 1-7.
Getting Started
impedance).
1-9