3.6

Manual Acquisition

Maximum 100 targets may be acquired manually depending on the acquisition
condition set on the ARP TGT menu.
3.6.1

Setting manual acquisition conditions

1. Roll the trackball to place the arrow in the ARP ACQ MODE box at the right
side of the screen and then push the right button to show the ARP TARGET
menu.
2. Roll the wheel to choose 1 ARP SELECT and then push the wheel.
3. Roll the wheel to choose MANUAL 100, AUTO 25, AUTO 50 or AUTO 75 as
appropriate and then push the wheel or the left button. For details see the
table on page 3-5.
4. Push the right button to close the menu.
3.6.2

Manually acquiring a target

By keyboard
1. Roll the trackball to place the cursor on the target you want to acquire.
2. Press the [ACQ] key.
By trackball
1. With the cursor inside the effective display area, roll the wheel to show
"TARGET DATA & ACQ" or "ACQ" in the guidance box.
2. Roll the trackball to place the cursor on the target you want to acquire.
3. Push the left button to acquire the target.
[ARP TARGET MENU]
1 ARP SELECT
MANUAL100/
AUTO
25/
AUTO
50/
AUTO
75/
AUTO
100
2 ALL CANCEL
3 REF TARGET VECTOR
ARP TARGET menu
3. ARP OPERATION
3-7