ZyXEL Communications IES-5000 Support Notes page 8

Zyxel ies-5000: user guide
Hide thumbs Also See for IES-5000:
Table of Contents

Advertisement

IES-5000 Support Notes
on the IES-5000, another VLAN (to which the two ports are a member of) need to be
configured.
1. IES-5000 Settings
1.1 VLAN settings
Create a VLAN group with VID 10 and set Port 1, ENET1 and ENET2 to be members
of this VLAN.
CI command:
TGE1> vlan set 10 up1 fix untag
TGE1> vlan set 10 up2 fix untag
TGE1> vlan name 10 VLAN10
TGE1> port pvc vlan 7-1-0/33 10 join untag
Create a VLAN group with VID 20 and set Port 2, ENET1 and ENET2 to be members
of this VLAN.
CI command:
TGE1> vlan name 20 VLAN20
TGE1> vlan set 20 up1 fix untag
TGE1> vlan set 20 up2 fix untag
TGE1> port pvc vlan 7-2-0/33 20 join untag
Create a VLAN group with VID 200 and set slot 7, Port 1, Port 2, ENET1 and ENET2
to be members of this VLAN.
CI command:
TGE1> vlan name 200 VLAN200
TGE1> vlan set 200 up1 fix untag
TGE1> vlan set 200 up2 fix untag
TGE1> port pvc vlan 7-1-0/33 200 join untag
TGE1> port pvc vlan 7-2-0/33 200 join untag
1.2 PVID settings
After creating the three VLANs, you need to set the PVID on the ports.
8
All contents copyright (c) 2005 ZyXEL Communications Corporation.

Advertisement

Table of Contents
loading

Table of Contents