IES-5000 Support Notes
VLAN. Also enable egress tagging on ENET 1.
TGE1> vlan name 20 VLAN20
TGE1> vlan set 20 up1 fix tag
TGE1> port pvc vlan 7-1-0/33 20 join untag
1.2 VC profile setup
For profile setup, create a Defval_CBR VC profile with the Encap, Class, PCR and
CDVT settings as shown. Make sure the profile has the same LLC-based
encapsulation setting as the IES-500 and the CBR class is set with a higher ATM QoS
priority .
CI command
TGE1> profile atm set Def_CBR cbr 300000
1.3 Multiple PVCs setup
Since we want to give the 0/33 VPI/VCI a higher priority, change the VCI/VPI
priority in the Defval_CBR profile that was just created.
CI command:
TGE1> port pvc set 7-1-0/33 Defval_CBR llc 0 7
Create another PVC with a VPI/VCI of 0/34 and apply the DEFVAL profile to this
channel.
CI command:
TGE1> port pvc set 7-1-0/34 Defval llc 20 0
2. Prestige 660R-61(P791) Settings
On the CPE, we need to configure two channels: 0/33 and 0/34. The previous
application example already shows you how to configure a channel (0/33) on the CPE.