Status Read Command

Format
The command is sent from PC to the projector with
the format below;
'CR' [Command] 'CR'
Command: one character (refer to the command
table below.
The projector decodes the command and returns the
'Character string' with the format below;
Command
Function
CR0
Status Read
Temperature
CR6
Read
The tables on pages 74 and 75 show the typical command lists for controlling the projector. Please consult your
local dealer for further information of other commands.
ViewSonic
Projector
Return
00
Power On
80
Stand-by mode
40
Countdown
20
Cooling down
10
Power Malfunction
28
Cooling down at the temperature anomaly
Stand-by mode after Cooling down at the temperature
88
anomaly.
24
Cooling down at Power Management mode
04
Power Management mode after Cooling down
Cooling down after the projector is turned off when the
21
lamps are out.
Stand-by mode after Cooling down when the lamps
81
are out.
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
%3 = Temperature at Sensor 3 (˚C)
(ex.) %1 = 12.3˚C, %2 = 23.4˚C, %3 = 34.5˚C
%1 %2 %3
--> The projector displays "12.3 23.4 34.5"
( For each sensor, two digit and the tenth place
numbers are displayed with a space between each
temperature.)
?