Speed/Disable:
This setting has six modes—100M Full, 100M Half, 10M Full, 10M
Half, Auto and Disable—for speed or port disable selections.
Note: If speed set to be exist 100M full mode or 10M full mode, flow control have fixed
setting to disable

Flow Control:

This setting determines whether or not the Switch will be handling
flow control. Set FlowCtrl to Enable for avoiding data transfer
overflow. Or it sets to Disable; there is either no flow control or other
hardware/software management.
When the port is set to forced mode, then the flow control will
automatically set to Disable.
Note: Sending packets between two groups may cause packet lost
QoS:
In some ports that need to have a high priority to manage the data
transfer, QoS should be change. Set the port's QoS to high to
determine the port will always transfer their data first.
Note: QoS function can be working in any port either from port 1 to port 24 or from
port 25 to port 52.However, QoS setting can not be working in different port
group. For example, we set port 1 and port 25 priority high. When we send
packet to port 26, port 1's QoS doesn't work. In the same way, port 25's QoS
doesn't work when we send packet to port 2.