System Health Monitor; System Fan Monitor - Supero AS2041M-32R Plus User Manual

Supermicro as2041m-32r plus servers: user guide
Table of Contents

Advertisement

Redirection After BIOS POST
Options are Disable (no redirection after BIOS POST), Boot Loader (redirection
during POST and during boot loader) and Always (redirection always active).
Note that some OS's may not work with this set to Always.
Terminal Type
Selects the type of the target terminal: ANSI, VT100 and VT-UTF8.
VT-UTF8 Combo Key Support
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/
VT100 terminals.
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information. Op-
tions are No Delay, 1 sec, 2 secs and 4 secs.

System Health Monitor

CPU Overheat Temperature
Use the "+" and "-" keys to set the CPU temperature threshold to between 65
o
and 90
C. When this threshold is exceeded, the overheat LED on the chas-
sis will light up and an alarm will sound. The LED and alarm will turn off once
the CPU temperature has dropped to 5 degrees below the threshold set. The
o
default setting is 72
C.
Other items in the submenu are systems monitor displays for the following in-
formation: CPU1 Temperature, CPU2 Temperature, CPU3 Temperature, CPU4
Temperature, (for 4U systems), System Temperature, CPU1 Vcore, CPU2 Vcore,
CPU3 Vcore, CPU4 Vcore (for 4U systems), 3.3V Vcc, +5Vin, +12Vin, 5V standby
and battery voltage.

System Fan Monitor

Fan Speed Control
This feature allows the user to determine how the system will control the speed of
the onboard fans. Select "Workstation" if your system is used as a Workstation.
Select "Server" if your system is used as a Server. Select "Disable" to disable
the fan speed control function to allow the onboard fans to continuously run at
7-15
Chapter 7: BIOS