CPU Heat Sinks

The use of active type heat sinks are recommended. Connect the heat sink fans to
the appropriate fan headers on the serverboard.
Installing the Heat Sink
1.
Do not apply any thermal grease to the
heat sink or the CPU die; the required
amount has already been applied.
2.
Place the heat sink on top of the CPU so
that the two mounting holes are aligned
with those on the retention mechanism.
Also, the the heat pipes of all four heat
sinks (visible on one side of the heat
sink) should face toward the edge of the
serverboard.
3.
Screw in both screws until just snug. (Do
not over-tighten the screws, which may
damage the CPU.)
4.
After checking that the heat sink is sit-
ting level on the CPU, fully tighten the
twoscrews.
Uninstalling the Heat Sink
Warning: We do not recommend removing the CPU or the heat sink.
However, if you do need to uninstall the heat sink, please follow these
!
instructions to avoid damaging the CPU or the CPU socket.
1.
Unscrew and remove the heat sink screws in the sequence shown in the
picture on the right.
2.
Hold the heat sink as shown in the picture on the right and gently wriggle to
loosen it from the CPU. (Do not use excessive force when doing this!)
3.
Once the heat sink is loosened, remove it from the CPU socket.
4.
Clean the surface of the CPU and the heat sink to get rid of the old thermal
grease. Reapply the proper amount of thermal grease before you re-install
the heat sink.
Screw
Heat pipes
5-4
Screw