7 Align the memory module's edge connector with the alignment key of the
memory module socket, and insert the memory module in the socket.
See Figure 3-16.
NOTE:
The memory module socket has an alignment key that allows you to install
the memory module in the socket in only one way.
Figure 3-16. Inserting and Removing a DIMM
1
memory module
3
memory module socket ejector (2)
8 Press down on the memory module with your thumbs to lock the memory
module into the socket. See Figure 3-16.
When the memory module is properly seated in the socket, the ejectors on
the memory module socket align with the ejectors on the other sockets
that have memory modules installed.
9 Repeat step 5 through step 8 of this procedure to install the remaining
memory modules in the approved configurations. See Table 3-2.
10 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 64.
11 Replace the system-board assembly. See "Installing a System-Board
Assembly" on page 62.