Code
Log in BMC Cause
8301h
No
8302h
No
8400h
Yes
F001h
No
F002h
No
F003h
No
F004h
No
32
About Your System
SMBIOS Not Enough Space In
F000
SMBIOS Not Enough Space In
F000
Redirect Memory Error
System Event Log Full
BMC FRU Header checksum
bad
BIOS Update BMC FRU failed
BMC FRU Internal Area
checksum bad
Corrective Actions
See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
Check the SEL for details
on the events, then clear
the SEL.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.