Code
Log in BMC Cause
0123h
Yes
0150h
Yes
0151h
Yes
0152h
Yes
0153h
Yes
0160h
Yes
0161h
Yes
28
About Your System
CPU4 Thermal Failure due to
PROCHOT#
Processor failed BIST
Processor failed BIST
Processor failed BIST
Processor failed BIST
CPU1 Processor missing
microcode
CPU2 Processor missing
microcode
Corrective Actions
Ensure that the processor
heat sinks are properly
installed.
See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
A BIOS update is required.
If the problem persists, see
"Getting Help" on page 143.
A BIOS update is required.
If the problem persists, see
"Getting Help" on page 143.

Hide quick links: