4.7.1 Auto Media Sensor Calibration

Auto Media Sensor Calibration automatically establishes the optimum sensing values for the media you are using in the
printer.
Note: Before calibrating, be sure the media sensor is set for the appropriate media type, see Section 4.5.2; also, ensure that the
Printhead Carrier Assembly is latched down and the cover is closed.
To automatically calibrate the media sensor:
1. With the desired media loaded, hold the
until the
light turns off then release it.
STOP
2. Next press the
PAUSE
and Low values to be used.
3. Upon completion, one of the following lights will flash five times to denote the result of the auto calibration attempt:
light = Successful calibration. Proceed to Step 4.
STOP
light = Unsuccessful calibration, try again. If the calibration continues to fail proceed to Section 4.7.2.
ERROR
Note:
If you wish to discard the changes and revert back to the previous calibration simply turn off the printer before Step
4.
4. Now save the changes and resume
briefly. Wait until the
M-4206
CANCEL
button. The printer will feed approximately ten inches of media to calculate the TOF Delta
light goes off.
STOP
button while powering up the printer. Continue to hold the button
by pressing the
PAUSE
+
buttons simultaneously and
CANCEL
31