Power Connection

Before connecting the saw to power, read through
SECTION 2: CIRCUIT REQUIREMENTS to
check that your setup follows the safety and circuit
requirements for your model.
Open the power connection box shown in Figure
48.
Figure 48. Power connection box.
Connect the power wires to the terminals shown
in Figure 49, tighten the strain relief so the wires
can't be pulled from the terminals, then close the
power connection box.
Note for G0623X3: If using a phase converter,
connect the manufactured power leg to the S ter-
minal to prevent damage (see Page 15).
Figure 49. Main terminal boxes.
-32-
Power
Connection Box
G0623X
Ground
S
R
G0623X3
Ground
T
S
R

Test Run

After the machine has been connected to the
power source, the machine MUST be test run to
make sure all the controls and safety components
function properly before the machine is placed
into regular operation.
It is extremely important that all steps in this sec-
tion be followed very closely, in the order given,
to ensure that the safety features are tested cor-
rectly.
Before beginning the test run, review the power
controls shown in Figure 50 and Controls &
Features on Page 9.
STOP Button
Figure 50. Main power controls.
If the machine does not operate as stated
in this section, review the troubleshooting
section on Page 49. If you need additional
help, call Tech Support at (570) 546-9663.
DO NOT place a machine into regular opera-
tion if you suspect that it is malfunctioning,
or serious injury could occur.
G0623X/G0623X3 10" Sliding Table Saw