Electrical Specifications; Suggested Individual Branch Circuit; Receptacle And Fuse Types - Danby DPAC10030 Owner's Manual

Portable 3 season home comfort
Table of Contents

Advertisement

Electrical Specifications

1. All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and
operation of this unit.
3. Model DPAC10030 draws 12.0 nameplate amps.
under Cooling Mode and may be used in any
properly wired, general purpose 15 amp
household grounded receptacle.
4. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a qualified
electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with
this unit, use an approved "air conditioner"
extension cord only. (available at most local
hardware stores)
5. The manufacturers nameplate is located on the
rear panel of the unit and contains electrical and
Unit Specifications:
Cooling Capacity
Dehumidifying Capacity
Noise Level
Power Source
Refrigerant
Internal Water Tank Capacity
External Water Tank Capacity
Unit Weight
Unit Dimensions (inches) W x D x H
Unit Dimensions (cm) W x D x H
Fan Speeds
Control Panel (Illuminated)
Remote Control
Time of Day Clock
Auto - Timer
Power Consumption:
Cooling
Dehumidifying
Fan
NOTE: Specifications are subject to change without notice, for further improvements.
other technical data specific to this unit.
6. To avoid the possibility of personal injury, always
disconnect the power supply to the unit, before
installing and/or servicing.

Suggested Individual Branch Circuit

Nameplate Amps
12.0
AWG- American Wire Gage
* Based on copper wire at 60°C temperature rating.

Receptacle and Fuse Types

Rated Volts
Amps
Wall Outlet
Fuse Size
Time Delay Fuse
(or circuit breaker)
DPAC10030
10000Btu/h
55 Pints (26 L / 24 Hrs)
50 dB (A)
115 V / 60 Hz
R22
3.0 L (6.3 Pints)
15 L (31.7 Pints)
40 kg (88.2 lb.)
17-3/8" x 18-1/4" x 33-9/16"
44.1 x 46.3 x 85.3
3
Soft Touch Controls
Yes
Yes
Yes
1200 Watts (12.0 Amps)
1200 W (12.0 Amps)
90 W (0.8 Amps)
3
Table 1
AWG Wire Size*
14
Table 2
125
15
15
Plug Type

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents