DRAINING
EXCESS WATER
1) Drain excess water from the tank by placing a pan under the
drain water outlet. (Fig. 1)
2) Remove the drain plug and let the water drain into the pan.
3) When the water stops draining out, replace the drain plug, and
put the tube back in with the clip pointing up.
4) Remove the pan of water.
5) Operate the unit in Fan mode to dry the interior of the unit.

INSTALLATION

ELECTRIC SHOCK HAZARD: To avoid the
possibility of personal injury, disconnect power to
the unit before installing or servicing.
Caution: To avoid installation/operation
difficulties, read these instructions thoroughly.
LOCATION
Use this portable air conditioner on a level
surface only, as inclinations greater than 3° can
cause water overflow.
Flexible Exhaust Hose (13cm) & Exhaust nozzle
connector (2 pcs)... from 17
1
/
" (135cm)
6
Adjustable window door slider kit (3 pcs).....
from 28
/
"(72cm) up to 80" (203cm)
1
3
Fixture..... (2 pcs)
Screws...(8 pcs)
NOTE: The exhaust/window kit must be
installed at all times when the unit is operating
under AIR CONDITIONING mode.
Instructions for assembling the window
adapter kit (Fig. 3).
a) Insert tube adapters through the back of the
window panel.
b) Secure each tube adapter with four screws
through the front of the window panel.
c) Insert window panel extensions into window
panel. Lightly tighten the screws in the window
panel to hold the extensions in place.

OPERATING INSTRUCTIONS

7
/
(45cm) up to 53
10
5
Fig. 1
INSTALLATION ACCESSORIES
Fig. 2
Flexible Exhaust Hose
Exhaust Nozzle
Connector
Screws
Adjustable Window Slider Kit:
28 1/3" (72cm)- 80" (203cm)
There should be at least 11.8" (30cm)
clearance between the unit and any other
objects or building structures, and should be
installed on a level surface. The unit does
not have to be vented outside during
Dehumidifying or Fan Only mode operation.
Fig. 3
Tube Adapters
Fixture
Back of
Window Panel