Set program change mode
Normally program change messages are sent via MIDI
OUT on the channels specified by the UPPER, LOWER
and BASS channel settings in the MIDI menu. This way
your external device will receive program change mes-
sages and follow as you change programs.
By setting the Program Change Mode to "Off" or
"Receive" your external device will not follow as you
change programs.
6
Turn off all drawbars for the selected manual
By doing this no sound is generated internally.
7
Play!

RECORDING MIDI IN A SEQUENCER

When recording MIDI in a sequencer you need to keep
track of the MIDI channel setting for
BASS
, below referred to as "keyboard".
When recording MIDI data to be played back on
the Nord C1 Combo Organ:
• Use channel settings 1 -16 for each keyboard individu-
ally. This it the default setting.
• Never set the keyboards to the same channel.
Note: The default behaviour of many sequencer applica-
tions is to merge incoming data into one MIDI channel. For
the correct behaviour set the MIDI channel setting of your
sequencer program to OMNI, sometimes also describes as
"Any" or "All". Please refer to the documentation of your se-
quencer software for more information.
When recording MIDI data to be played back on
other equipment:
• Use channel settings E1 - E9. This setting will use the
keyboards normal trigger response, and incorporate
velocity sensitive data. When using this setting,
is disabled for the selected keyboard.
Please refer to "The Keyboard" on page 5 for more informa-
tion.
INSTALLING THE USB DRIVER (WIN-
DOWS ONLY)
A driver is not needed for computers running OS X operat-
ing systems. The Windows USB driver is compatible with
the following Windows versions:
UPPER
LOWER
,
and
MIDI IN
• Windows 2000
• Windows XP (x32 and x64 versions)
The Driver can be found at www.clavia.se
1
Connect a USB cable between the unit and
your computer
The "Found New Hardware" wizard should appear. Fol-
low the on-screen instructions.
USB-cable is an accessory item and sold separately.

UPGRADING THE OS

OS upgrades can be found at www.clavia.se when availa-
ble.
The currently installed OS version is shown in the
power up.
1
Download the latest OS version
2
Connect a USB cable between the unit and
your computer
3
Un-compress and run the downloaded appli-
cation
Wait for the application to find your instrument. Click
the UPDATE button. The progress bar will show you
when the update is finished.

ABOUT PROGRAM SYSEX DUMPS

Program Sysex Dumps can be used for storing a single pro-
gram (Dump One) or the complete program bank (Dump
All) including Live 1 and Live 2 on an external device such
as a computer, or for transferring program data between
two units.
• For sending program Sysex messages, please refer to
"The MIDI Menu" on page 15.
• MIDI Sysex data will be received regardless of MIDI
channel setting.
• For a Dump All to be received, Memory Protect must be
turned off. Please refer to "The System Menu" on
page 15.
• A Dump One will be received regardless of Memory
Protect setting, but needs to be stored in order to not
get lost.
• While Program Sysex messages are received, the dis-
play will indicate "
RCV
" in a flashing manner.