Command 1: Channel Settings - Casio EA-200 Technical Reference

Casio ea-200 calculator-tools: user guide
Hide thumbs Also See for EA-200:
Table of Contents

Advertisement

Command 1: Channel Settings

{ 1, Channel, Operation, Post-Processing }
1. Channel
0
Clear all Command 1 data.
1
Specify CH1.
2
Specify CH2.
3
Specify CH3.
4
Specify SONIC channel.
5
Specify Digital In channel.
6
Specify Digital Out channel.
10 Specify mic.
11 Specify Analog Out.
12 Specify speaker.
2. Operation
Analog CH1, CH2, CH3
(Channel = 1, 2, 3)
0
Clear Command 1 data of specified channel.
1
Auto-ID
Perform sampling using automatically recognized sensor.
Perform 0 to 5V sampling when recognition is not possible.
2
Voltage sampling
10V
4
Resistance sampling 1–100kΩ
5
Period sec
6
Frequency Hz
7
Temperature –29 to 130°C
8
Temperature –4 to 266°F
9
Light quantity 100 to 999
10 Voltage sampling 0 to 5V
11 Time sec (Relative time sampling from sampling start)
SONIC
(Channel = 4)
0
Clear Command 1 data of SONIC channel.
1
Auto-ID
Perform sampling in automatically detected unit.
2
Meter
3
Feet
5
Period sec
6
Frequency Hz
11 Time sec (Relative time sampling from sampling start)
Digital I/O
Pin: Clock: 1
GND: 1
Signal: 8 (8-bit TTL 0 to 5V)
Digital In
(Channel = 5)
0 Clear Dig I channel information.
1 Active
Read information of digital connector Pin 8.
0 to 255
Digital Out
(Channel = 6)
0
Clear Dig O channel information.
1 to 32
Number of loops
Number of outputs of list values
– 9 –

Advertisement

Table of Contents
loading

Table of Contents