Download Print this page

CyberPower CPS1250AVR User Manual page 11

Cyberpower systems user manual powerpanel plus tm software cps1250avr

Advertisement

EXPECTED RUNTIME IN MINUTES
Desktop PC with 15" Monitor
Desktop PC with 17" Monitor
Desktop PC with 21" Monitor
Tower PC with 21" Monitor
REPLACING THE BATTERY
CAUTION!
Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of
personnel knowledgeable of batteries and their precautions.
CAUTION!
Use only the specified type of battery. See your dealer for replacement batteries.
CAUTION!
The battery may present risk of electrical shock. Do not dispose of battery in a fire, as it may explode. Follow all local ordinances regarding
proper disposal of batteries.
CAUTION!
Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic.
CAUTION!
A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the battery:
1.
Remove all watches, rings or other metal objects.
2.
Only use tools with insulated handles.
3.
Do not lay tools or metal parts on top of battery or any terminals.
4.
Wear rubber gloves and boots.
5.
Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. CONTACT WITH GROUNDED
BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during installation
and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).
TO REPLACE THE BATTERY
1.
Turn off and unplug all connected equipment.
2.
Turn the UPS off and unplug it from the AC power source.
3.
Turn the UPS upside down.
4.
Remove the 6 retaining screws.
5.
Turn the UPS right side up and remove the outlet cover.
6.
Remove the battery from the compartment.
7.
Disconnect the battery wires from the battery.
8.
Install the replacement battery by connecting the
negative (-) terminal of the battery.
9.
Slide the battery back into the compartment.
10. Replace the outlet cover and the 6 retaining screws.
11. Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.
REMINDER: Batteries are consider HAZARDOUS WASTE and must be disposed of properly. Contact your local government for more information
about proper disposal and recycling of batteries.
72 - 100
56 - 80
45 – 65
40 - 60
red wire to the positive (+) terminal of the battery
9
CPS1250AVR
Guaranteed Uninterruptible Power System
and connecting the black wire to the

Advertisement

loading

This manual is also suitable for:

Powerpanel plus