Download Print this page

Laser Safety; Dimensions (Unit: Mm) - Omron Z500 Series Product Information

Profile measuring system
Hide thumbs Also See for Z500 Series:

Advertisement

Monitor
Monitor
Item
Panel size
Panel type
Resolution
Input signal
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Weight (including packaging)
Accessories

Laser Safety

The Z500-SW2T Sensor Head is a Class 2 Laser Product ac-
cording to EN60825-1 (IEC60825-1) and Class II Laser Prod-
uct according to FDA (21 CFR1040.10) (see note). The
Z500-SW6 and Z500-SW17 Sensor Heads are Class 3B and
Class IIIB Laser Products, respectively. The Z500 Series is
meant to be built into final system equipment. Pay special at-
tention to the following precautions for the safe use of the
product:
Note: Europe: Class 2 and Class 3B of EN60825-1: 1994 = IEC60825-1: 1993
U.S.A.: Class II and Class IIIB of FDA (21 CFR1040.10)
Z500-SW2T
Wavelength
650 nm
Maximum pulse duration 10 ms
Cycle
0.5 to 10 ms
Peak power
1 mW max.
Class
2

Dimensions (Unit: mm)

Sensor
Z500-SW2T
Receiver
Light
Z500
Model
5.5 inches
TFT color liquid crystal
320 × 240 dots
NTSC composite video (1.0 V/75 Ω)
20.4 to 26.4 VDC
Approx. 700 mA
Operating: 0 to +50 °C, Storage: -25 to +65 °C (with no icing or condensation)
Operating and storage: 35 to 85 %RH (with no condensation)
Approx. 870 g (Unit: Approx. 610 g)
Operation manual, 4 mounting brackets
Z500-SW6/Z500-SW17
658 nm
17.5 ms
0.5 to 25 ms
15 mW max.
3B
Optical axis
26.4
Reference plane
20
16
12
Reception axis
(4)
Measurement center
4
3
Monitor
Emission axis
Emitter
18.1
Reference plane
Vinyl-insulated round cable 6.8 dia.
Standard length: 2 m
Liquid Crystal Monitor
F150-M05L
(1)Use this product as specified in the operation manual. Oth-
erwise, you may be exposed to hazardous laser radiation.
(2)The Z500 series radiates laser beams in the visible light
range. Do not expose your eyes directly to the laser radi-
ation. Ensure that the laser beam path is terminated dur-
ing use. If a mirror or shiny surface is positioned in the
laser beam path, ensure that the reflected beam path is
also terminated. If the Unit must be used without terminat-
ing the laser beam path, position the laser beam path so
that it is not at eye level.
(3)To avoid exposure to hazardous laser radiation, do not dis-
place nor remove the protective housing during operation,
maintenance, and any other servicing.
(4)The user should return the product to OMRON for all repair
and servicing.
(5)As for countries other than those of Europe and the U.S.A.,
observe the regulations and standards specified by each
country.
Two, 4.5-dia. holes
65
Operation indicators
4
17 dia.
57
20
Connector
B-51