8-/32-Kbyte Memory ID Tag
V680-D8KF@@, V680-D32KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit)
Controller or ID Sensor
Unit transmission
speed setting
Normal mode
Read
Write
High-speed mode
Read
(See note 2.)
Write
Note 1. These are the TAT values for a baud rate of 115,200 bps. For information on the TAT for baud rates other than 115,200 bps, refer to the
User's Manual.
2. When multi-access or FIFO is selected as the transmission option, the transmission time will be the same as in normal mode even when
the transmission speed is set to high-speed mode.
3. The value given for TAT data assumes that communications settings for the V680-CA5D01/02-V2 ID Controller are as follows:
Data length: 8 bits, Stop bits: 1, Parity: Odd.
In this example, communications are continuous, with no gaps between characters.
4. The number of bytes of TAT data is the number of bytes when ASCII is specified as the code.
V680 Series
34
Command
Write verification
setting
---
Yes
No
---
Yes
No
RFID System
Number of bytes to
TAT (ms) (See note 1.)
processed (byte)
100
172
256
388
512
746
1,000
1,430
2,000
2,820
100
231
256
494
512
929
1,000
1,759
2,000
3,449
100
192
256
408
512
766
1,000
1,450
2,000
2,840
100
117
256
255
512
485
1,000
925
2,000
1,815
100
163
256
348
512
655
1,000
1,241
2,000
2,431
100
142
256
296
512
551
1,000
1,040
2,000
2,030