Download Print this page

Omron SYSMAC CS1 Brochure page 6

Hide thumbs Also See for SYSMAC CS1:

Advertisement

Further improvements to communications f unctions.
Seamless networks increase production site transparency.
The evolution of
The Solution for Communicating
across Network Levels
the SYSMAC CS1 is
The SYSMAC CS1 enables FINS
accelerating advances in
message communications across a
maximum of eight levels (See note)
(using CX-Programmer Ver. 4.0 or
the production site.
higher) in comparison with three levels
in previous OMRON systems
Expansion up to eight levels lets you
build a seamless communications
system for sending FINS messages
across multiple levels of Ethernet and
Controller Link networks.
Note: For CPU Unit Ver. 2.0 or later.
A Wide Range of Systems,
from Small-scale to Large
OMRON offers a full lineup of reliable
PLCs including the "flagship" CS1
Series, and ranging from the small-
scale CQM1H to the large-scale CV
Series. The CS1 Series meets the needs
not only of small-scale to large-scale
systems, but of distributed systems as
well. This allows the construction of the
optimum system for the scale and
applications of the production site.
High Event Responsiveness and High-speed Instruction Execution
The new CS1 has an operating mode
that allows parallel processing for
program execution and peripheral
services. This has the following benefits.
Fast exchange with host computers of
large amounts of data, without
dependence on the program capacity of
the new CS1.
Smooth refreshing of data exchanged
with SCADA software without variations
in timing.
Cycle time not affected if communications
traffic or networks increase when
expanding facilities in the future.
Peripheral service
Peripheral services cannot
be executed in shorter period
than cycle time.
10
Flexible System Building
Based on the DeviceNet
The CS1 Series supports the worldwide
multivendor bus standard, DeviceNet.
Component connections in a
multivendor environment are greatly
enhanced by connecting to up to 64
nodes for a wide range of FA
applications, and by device profiles and
configurator tools that ensure high
reliability and easy maintenance.
Production systems can be configured
even more flexibly by incorporating
products such as the MULTIPLE I/O
TERMINAL.
Functions for Better Ethernet
Support
Ethernet is becoming an increasingly
important standard for information
networks. Up to eight socket interfaces
for TCP/IP and UDP/IP are supported, in
addition to FINS messages, FTP file
transfers, and mail notification, so that
production management can now be
organically linked with the production
site.
Host
SCADA software
Normal mode
Parallel processing mode
(Instruction execution)
(Peripheral servicing)
Peripheral servicing
Can be executed
in shorter period
than cycle time.
I/O refresh
I/O refresh
Parallel processing
Add a Redundant Optical Ring
to Your Controller Link
Communications
A redundant network configuration will
keep communications flowing over the
duplicate ring-shaped path in the event
of a broken optical fiber, preventing
system malfunction.
Fast large-volume data
exchange
No variations in data
exchange timing
Peripheral services
independent from
cycle time.
Cycle time
CS1
Response time:
Approx. 1/3
Sending/receiving FINS
commands and other
event processing.
Event services with
Special I/O Units, CPU
Bus Units, and Inner
Boards.
Peripheral and RS-232C
port servicing.
Event services using
Communications Board.
Remote Monitoring via the Web
Connecting via an ONC enables remote
monitoring from a Web browser with a
user-defined Web application (using
Web Tool Kit). It is also possible to
automatically collect data on a Memory
Card mounted to an ONC and
automatically transfer data to the host
PLC (using Data Collection/Distribution
Software).
Head office, remote office,
Head office or remote office
home, business trip destination
• Web browser
• CX-Programmer
• CX-Programmer
Modem
Public telephone line
FINS message
Email
Ethernet
Modem
(Intranet)
Serial communications
CS1
Ethernet Unit
• TCP/IP or UDP/IP socket service
• FINS message communications
• Message client (SMTP) function
• FTP server function
DeviceNet
(File read/write to Memory Card)
Configurator
Controller Link
Controller Link Unit
Controller Link Unit
DeviceNet
Unit
Data links
CS1
FINS message
DeviceNet
FINS message
DeviceNet Slave
DRT2-series Series
CS1
Temperature
DeviceNet Unit
Controller (PID and
(can operate as
other parameter
master or slave)
settings possible
from the
DeviceNet
Configurator).
Head office,
remote office,
home, business
trip destination
• Web browser
Internet
Email
HTTP/socket
Automatic FTP transfer of
collected data
Open Network Controller
• Web server function
• Email client (SMTP)
• FTP client
(Collected data file
transferred to host using
ONC
FTP when transfer
conditions are met.)
• FINS message
communications
RS-232C
CS1
CJ1
CS1
Remote I/O communications
Programmable
Slave
CompoBus/S
Robot or
other device
11