Omron NS-CXDC1-V3 User Manual page 15

Ns-series cx-designer
Hide thumbs Also See for NS-CXDC1-V3:
Table of Contents

Advertisement

Item
Screen transfers
Multivendor support
Screen saver
String table support for alarms
and events
Disable function for screen
inputs
From CX-Designer Version 3.0 to Version 3.007
Item
CX-Designer
NS system software
Printer
Multivendor support
Ladder Monitor
Data log graphs
Previous versions
Previously, when uploading project data
from the PT, the user display on the PT
would change to the transfer screen. Also,
after transfer finished, it was necessary to
reset the PT.
---
---
---
---
Previous versions
Version 3.0
Version 8.0
---
---
---
A line appeared on the data log graph while
data was being logged and then blank
spaces occurred at times when no data
was logged.
B
A
Logging was stopped.
No data logged.
New version
When uploading project data, it is no longer
necessary to change to the transfer screen
while uploading, nor is it necessary to reset
the PT when the transfer has finished. Now,
the user can continue operating the PT
screens even while uploading.
The PT can now be connected to the fol-
lowing devices.
• Rockwell Automation (Allen-Bradley)
SLC500 Controller, MicroLogix, PLC-5,
CompactLogix, and ControlLogix
• Modbus RTU-compatible devices
The time until the screen saver starts can
be indirectly specified.
Alarm and event message text strings can
now be viewed from string tables.
It is now possible to enabled or disable
inputs and outputs to the entire screen
when a specified communications address
is turned ON or OFF.
New version
Version 3.007
Version 8.1
PictBridge-compatible printers are now
supported (except they are not supported
by the NS5-@@0@, NSJ5-@@0@, and
NSH5).
The following PLCs can now be connected
to an NS-series PT.
• Yokogawa Electric FA-M3-series and FA-
M3R-series PLCs.
• CJ2-series PLCs are now supported.
• The host connected to an NS-series PT
over an EtherNet/IP network can now be
monitored.
It is now possible to display a dialog box
asking for a password if data will be modi-
fied, such as when changing present val-
ues.
A setting has been added to provide an
option to compress the times when data
was not logged so those times will not be
displayed. This way only logged data will be
displayed as one continuous line.
B
A
Periods when logging
was stopped are dis-
played on a reduced
time scale.
Display showing compressed time when no
data was logged.