Ns series programmable terminals

Advertisement

PLC Series
C Series
CV Series
(See note 3.)
CVM1 Series
(See note 3.)
CompoBus/S
master control
unit
Note 1: Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01
RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect.
2: The CQM1H-CPU11 does not have a built-in RS-232C port, so connect to the
peripheral port to the PT with a CS1W-CN118 Connecting Cable.
3: CPU Units of CVM1/CV-series PLCs without the suffix –EV@ cannot be connected.
Settings at the Host
When using the host link method, the settings shown below must be made at the host
(depending on the unit, some of these settings may not be necessary, or settings not shown
here may be necessary).
Item
I/O port
Communications speed
Transfer code
Parity
1-to-1/1-to-N
Command level
Unit #
Note 1: Set the Host Link communications speed (baud rate) to 9600 bps or 19200 bps with
the Communications Setting menu item in the CX-Designer and the System Menu
for the NS-series PT. For details, refer to 1-4 Settings for Host Link.
2: The 1-to-N setting enables using a BCC (Block Check Character). It is not actually
possible to connect more than one NS-series PT in a single Host Link.
The setting methods for each type of unit are described in the following.
CPU Units with Built-in Host Link
Function
CPM1-10/20/30CDR-@+CPM1-CIF01
CPM1A-10/20/30/40CD@-@+CPM1-
CIF01
CPM2A-30/40/60CD@@-@+CPM1-
CIF01 (Peripheral port connection)
CPM2C-10/20@@@@@@-@
(See note 1.)
CQM1-CPU21-E
CQM1-CPU41/42/43/44-EV1
CQM1H-CPU11/21/51/61 (See note 2.)
CV500-CPU01-EV1
CV1000-CPU01-EV1
CV2000-CPU01-EV1
CVM1-CPU01-EV2
CVM1-CPU11-EV2
CVM1-CPU21-EV2
SRM1-C02-V2
RS-232C
Set the same baud rate as set at the NS-series PT (See note 1.)
ASCII, 7 data bits, 2 stop bits
Even
1-to-N (See note 2.)
Level 1, 2, 3
00
CPU Units Connectable with Host
Link Units or Expansion
Communications Board
C1000H-CPU01-EV1
C2000H-CPU01-EV1
C1000H-CPU01-EV1
C1000HF-CPUA1-EV1
C2000H-CPU01-EV1
CQM1H-CPU51/61
CV500-CPU01-EV1
CV1000-CPU01-EV1
CV2000-CPU01-EV1
CVM1-CPU01-EV2
CVM1-CPU11-EV2
CVM1-CPU21-EV2
Switch Setting
7
Host Link Unit/
Communications
Board
C500-LK201-EV1
C500-LK203
CQM1H-SCB41
CV500-LK201
CV500-LK201

Advertisement