Download Print this page

Omron NS Reference Manual page 50

Hide thumbs Also See for NS:

Advertisement

Section2 Functions
NS series Macro Reference
SETTIME
Changes settings of internal clock of the PT
Applicable versions
Format
Function
Return Value
Example
System version 3 or higher
SETTIME(S)
Preset values for the specified address as S and writes them to the internal clock
of PT. Setting range for S is between $W0 and $W32765 or between $HW0 and
$HW8189. (See note)
Set the value in BCD format for addresses to be written.
Uses 3 words regarding the specified address as top.
Note: Index can be used for specifying the address.
None
Case that December 31, 2002 18:59:20 is set.
$W 100=H5920; $W101=H3118; $W102=H0212;
SETTIME($W100);
30

Advertisement

loading

This manual is also suitable for:

Ns-series