Section2 Functions
NS series Macro Reference
MOVEPOPWDOWN
Applicable versions
Format
Function
Return Value
Example
Reference
When setting macro "MOVEPOPWDOWN" for ON/OFF button, Word button, Command button and
Multifunction Object on a pop-up screen and moving the pop-up screen, select "Touch Off Timing". If
"Touch On Timing" is selected, the status of the object will be pressed.
Moves pop-up window down
System version 2 or higher
MOVEPOPWDOWN(n, y)
Move the pop-up window page number "n" to y down.
Setting range for "n" is 0 to 3999. If the value outside of the range or page number
which does not existed is specified, return value "-1" will be returned. There is no
restriction on setting value for "y". However, set the value to the pop-up screen in
order to be displayed inside of the screen. Part of the screen or whole screen may
be deleted depending on the set value.
0: Completed normally
-1: Specified no page
$W0=MOVEPOPWDOWN(10, 32);
'Move the pop-up window page number 10 to 32dot down,
'then return "0"to $W0. If pop-up screen is not displayed,
'return "-1" to #W0.