Download Print this page

Omron NS Reference Manual page 39

Hide thumbs Also See for NS:

Advertisement

Section2 Functions
NS series Macro Reference
MOVEPOPWRIGHT
Applicable versions
Format
Function
Return Value
Example
Reference
When setting macro "MOVEPOPWRIGHT" for ON/OFF button, Word button, Command button and
Multifunction Object on a pop-up screen and moving the pop-up screen, select "Touch Off Timing". If
"Touch On Timing" is selected, the status of the object will be pressed.
Moves pop-up window to the right
System version 2 or higher
MOVEPOPWRIGHT(n, x)
Move pop-up window page "n" to x dot right.
Setting range for "n" is 0 to 3999. If the value outside the range or screen number
that does not exist is specified, return value "-1" is returned. There is no restriction
on setting for "x". However, set the value in order to be displayed inside of the
screen. Part of the screen or whole screen may be deleted depending on the set
value.
0: Completed normally
-1: Specified no page
$W0=MOVEPOPWRIGHT (10,32);
'Move the pop-up screen page 10 to 32 dot right, then return "0" to $W0. If the
pop-up screen is not displayed, return "-1" to $W0.
19

Advertisement

loading

This manual is also suitable for:

Ns-series