Omron E5ZN-DRT Operation Manual page 72

Devicenet communications unit for e5zn temperature controllers
Hide thumbs Also See for E5ZN-DRT:
Table of Contents

Advertisement

Allocating I/O from the Configurator
Auto/Manual (Type Number 17, 18)
15
Auto/manual
Unit
Units 0 to 7
7,
(type number 17)
ch2
Auto/manual
Unit
Units 8 to 15
15,
(type number 18)
ch2
Setting Area 0/1 (Type Number 19, 20)
15
Setting area 0/1
Unit
Units 0 to 7
7,
(type number 19)
ch2
Setting area 0/1
Unit
Units 8 to 15
15,
(type number 20)
ch2
Unit Status (Type Number 23)
Temperature Controller Maintenance Flag
ON:
AT (autotuning) is being executed for the corresponding Temperature
Controller and the corresponding Temperature Controller is communi-
cating normally.
OFF:
AT (autotuning) is stopped for the corresponding Temperature Con-
troller and the corresponding Temperature Controller is communicat-
ing normally, or the unit number belongs to a Temperature Controller
that is not communicating normally.
14
13
12
11
10
Unit
Unit
Unit
Unit
Unit
7,
6,
6,
5,
5,
ch1
ch2
ch1
ch2
ch1
Unit
Unit
Unit
Unit
Unit
15,
14,
14,
13,
13,
ch1
ch2
ch1
ch2
ch1
ON:
The corresponding Temperature Controller is communicating nor-
mally and is being operated manually.
OFF:
The corresponding Temperature Controller is communicating nor-
mally and is being operated automatically, or the unit number belongs
to a Temperature Controller that is not communicating normally.
14
13
12
11
10
Unit
Unit
Unit
Unit
Unit
7,
6,
6,
5,
5,
ch1
ch2
ch1
ch2
ch1
Unit
Unit
Unit
Unit
Unit
15,
14,
14,
13,
13,
ch1
ch2
ch1
ch2
ch1
ON:
The corresponding Temperature Controller is communicating nor-
mally and is in setting area 1 status.
OFF:
The corresponding Temperature Controller is communicating nor-
mally and is in setting area 0 status, or the unit number belongs to a
Temperature Controller that is not communicating normally.
15 14 13 12 11 10
9
8
7
0
0 0 0 0
0
0 0
OFF: Within range (less than monitor
value for all channels of all Units)
ON: Outside range (monitor value or
higher for at least one channel)
• The Temperature Controller Power Status Flag indicates the status of the
power supplied to the Terminal Unit.
9
8
7
6
Unit
Unit
Unit
Unit
Unit
4,
4,
3,
3,
2,
ch2
ch1
ch2
ch1
ch2
Unit
Unit
Unit
Unit
Unit
12,
12,
11,
11,
10,
ch2
ch1
ch2
ch1
ch2
9
8
7
6
Unit
Unit
Unit
Unit
Unit
4,
4,
3,
3,
2,
ch2
ch1
ch2
ch1
ch2
Unit
Unit
Unit
Unit
Unit
12,
12,
11,
11,
10,
ch2
ch1
ch2
ch1
ch2
Bit
6
5
4
3
2
1
0
0
0
0
0
Temperature Controller Power Status Flag
OFF: Power is ON
ON: Power is OFF
Network Power Voltage Monitor Error Flag
OFF: Normal (higher than monitor value)
ON: Error (monitor value or lower)
Unit Maintenance Flag
OFF: Within range (less than monitor value)
ON: Outside range (monitor value or higher)
Section 4-3
5
4
3
2
1
Unit
Unit
Unit
Unit
2,
1,
1,
0,
ch1
ch2
ch1
ch2
Unit
Unit
Unit
Unit
10,
9,
9,
8,
ch1
ch2
ch1
ch2
5
4
3
2
1
Unit
Unit
Unit
Unit
2,
1,
1,
0,
ch1
ch2
ch1
ch2
Unit
Unit
Unit
Unit
10,
9,
9,
8,
ch1
ch2
ch1
ch2
0
Bit
Unit
0,
ch1
Unit
8,
ch1
0
Bit
Unit
0,
ch1
Unit
8,
ch1
57