Online Monitoring

Monitor communication units by using the following procedures.
1. Switch the Configurator to online (select [Network] - [Connection]).
2. Select a communication unit and right-click it to select [Monitor].
3. Monitor from the following screen.
4. Set threshold values on the monitor screen.
When you select [Change] after you modify a threshold value, the new value is set to the
sensor.
5. Select [Teaching...] to instruct operations to each sensor.

Sensor Maintenance

Select the [Maintenance] on the monitor screen to show the maintenance screen for the
sensors.
On the maintenance screen, the electrification time of the head and amplifier of each
sensor is displayed.
Electrification time threshold value for the head and amplifier (configured in the sensor
amplifier unit settings) will appear in each box when the electrification time of the head
and/or amplifier exceeds the corresponding value.
Select [Clear] to reset the electrification time to 0.
E3X-DRT21-S
82
User's Manual
Monitor detection levels for
each sensor.
Set set threshold values.
Monitor ON/OFF state. Yellow
means ON; black means OFF .
When a value exceeds its threshold
value, the corresponding checkbox
is checked.