Dimensions (Unit: Mm) - Omron E3S-CL Datasheet

Distance setting photoelectric sensor in metal housing

Advertisement

Others
Oil resistance/chemical resistance (E3S-CL2)
For the oil resistance ofE3S-CL2, the Sensor has passed
tests on the oils given in the following table. Refer to the table
for examining the oil to be used. Depending on the oil type,
however, the Sensor may not be able to exhibit its perfor-
mance.

Dimensions (Unit: mm)

E3S-CL1
E3S-CL2
54.5
E3S-CL
With Mounting Bracket Attached
Receiver
2-M4
15.4
Slotted hexagonal bolt
16
16.5
16.1
9.1
28
21
2
Emitter and optical
axis position
Sensing optical axis
Note: The output selector, mode selector and distance setting adjuster are exposed when the cover is opened.
Testing
oil clas-
JIS classi-
sifica-
fication
tion
Lubri-
---
Velocity No. 3
cant
Class 2
Daphne Cut
Water-in-
No. 5
soluble
coolant
Class 2
Yushiron Oil No. 2ac
No. 11
Yushiroken EC50T-3
Class W1
No. 1
Yushiron Lubic HWC68
Water-
Class W1
soluble
Gryton 1700D
No. 2
coolant
Class W2
Yushiroken S50N
No. 1
Note: 1 . E3S-C was submerged in the oils in the above table at 50°C for 240
hours, and passed the test of 100-M or more insulation resistance.
2 . For use in the environment where E3S-C is exposed to the oil other
than those in the above table, use the dynamic viscosity and PH in the
above table. Pre-check the oils since the sensor may be affected by
additives etc. in the oils.
23.8
7.3
6.2
4.2
9.2
12
19.7
Operation indicator
40
Stability indicator
1.1
37.2
42.6
40
44.7
Dynamic vis-
2
Product name
cosity (mm
/s)
at 40°C
2.02
Not less than
10 to less than
50
Less than 10
---
11.7
Stainless steel
4.2
20
Mounting holes
2-M4
25.4
2-M4
E3S-CL1: Vinyl-insulated round cable of 4 dia.
3 cores conductor cross-sectional area:
0.2 mm ² ; insulation diameter: 1.1 mm
Standard length: 2 m
E3S-CL2: Vinyl-insulated round cable of 4 dia.
3 cores conductor cross-sectional area:
0.2 mm ² ; insulation diameter: 1.1 mm
Standard length: 2 m
PH
---
7`9.5
7`9.9
7`9.2
7`9.8
A-117

Advertisement

loading

This manual is also suitable for:

E3s-cl1E3s-cl2