Basic Operating Information

Setting the Mode
The mode is set using the SET/RUN switch. Set this switch according to the operation to be performed.
Mode
SET
Select to set detection conditions, to teach the threshold value, etc.
Select for actual detection operation or to set the following: Manual adjust-
RUN
ment of thresholds, power adjustment, zero reset, or key lock.
Key Operations
The operation keys are used to switch the displays and set detection conditions. The functions of the keys depend on the current
mode.
Key
RUN mode
UP key
Increases the threshold.
DOWN
key
Decreases the threshold.
Depends on the MODE key setting.
MODE key
− Executes power tuning (default set-
− Executes a zero reset.
Time to Press Keys
If a specific time for pressing a key is not given in a procedure, press the key for approximately 1 second.
For example, if the procedure says "press the UP key," then press the UP key for approximately 1 second
and then release it.
Reading Displays
The information displayed on the main display and sub-display depends on the current mode.
For the default settings, the RUN mode displays will appear when the power supply is turned ON for the first time
Mode
Displays the incident light level,* function name, or
other information depending on the key operation.
Set
*The incident light level will be displayed even if
DIFF (differential operation) is set for the detection
For the default setting, the current incident light level
RUN
(See
The change in the incident light level will be dis-
note.)
played when DIFF (differential operation) is set for
Note: The information that appears on the displays can be set using the display switch function. Refer to Detailed Settings.

Basic Settings

Setting the Operation Mode
Select either light-ON or dark-ON operation.
Selection
LON (light-ON)
(default)
DON (dark-ON)
The setting method depends on the type of Amplifier Unit.
Type
Twin-output model
External-input
model
L
Adjusting the Power (as Required)
A-458
Description
Function
− Changes the setting forward.
− Changes the setting in reverse.
Switches the function to be set on the
ting).
Main display (red)
method.
will be displayed.
the detection mode.
The output will turn ON when the incident light level is above the threshold.
If DIFF (differential operation) is set for the detection method, the output will turn ON when an edge is detected.
The output will turn ON when the incident light level is below the threshold.
If DIFF (differential operation) is set for the detection method, the output will turn OFF when an edge is detected.
D
SET mode
Depends on the setting.
− Executes teaching.
Depends on the setting.
− Executes teaching.
display.
Sub-display (green)
Displays threshold value* or the setting of the func-
tion displayed on the main display depending on the
*The threshold value for the change in the incident
light level will be displayed if DIFF (differential oper-
ation) is set for the detection method.
For the default setting, the current threshold value
The threshold value for the change in the incident
light level will be displayed if DIFF (differential oper-
ation) is set for the detection method.
Description
Setting method
Set as the operation mode in SET mode.
Refer to 5. Detailed Settings.
Set using the operation mode selector.
key operation.
will be displayed.
Advanced Photoelectric Sensors