Omron D5C Datasheet

Touch switch

Advertisement

Quick Links

Touch Switch
D5C
Unique 18 mm dia. Capacitive Touch Switch
with Choice of Three Actuators is Activated
with Only a Very Slight Physical Contact
• Lightweight objects, such as thin wire or foil can be accurately
detected.
• Solid-state switch activates the moment its actuator comes in
contact with the object.
• Amplifier, operation indicator, and sensitivity adjuster are built-
in on all models.
• Conforms to IEC IP67 and NEMA Type 6, 6P.
• Actuators can be freely interchanged between switch units.
• A unique free-attachment version allows any kind of actuator
antenna to be attached.

Ordering Information

■ List of Models
Features
Usable by bending tip of antenna.
Overtravel of 20 mm max.
Cable
3 m
Actuator
Coil spring
Power source
DC
D5C-1DS0
AC
D5C-1AS0
Antenna only
D5C-00S0

Specifications

■ Characteristics
Model
Degree of protection
Durability
Supply voltage (operating voltage)
Rated frequency
Sensitivity setting range
Current consumption
Leakage current
Response time
Output current
Insulation resistance
Ideal for high-accuracy position con-
trol.
Overtravel of 3.5 mm max.
Plunger
D5C-1DP0
D5C-1AP0
D5C-00P0
DC
D5C-1D@0
Equivalent to IP67 (NEMA 6, 6P)
Mechanical: 10,000,000 operations min. (at rated overtravel value)
12 to 24 VDC (10 to 30 VDC), (ripple: 10% max.)
---
30 to 100 pF
17 mA max.
Circuit:
---
Antenna: 1 mA max.
2 ms max.
200 mA max. (resistive load)
50 MΩ min. (at 500 VDC) between lead wires and case
Any actuator can be attached.
Free-attachment
D5C-1DA0
D5C-1AA0
D5C-00A0
AC
D5C-1A@0
100 to 240 VAC (45 to 264 VAC), 50/60 Hz
50/60 Hz
---
Circuit:
2 mA max.
Antenna: 1 mA max.
8 ms max.
D5C
Touch Switch
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron D5C

  • Page 1: Ordering Information

    Unique 18 mm dia. Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact • Lightweight objects, such as thin wire or foil can be accurately detected. • Solid-state switch activates the moment its actuator comes in contact with the object.
  • Page 2: Output Circuit

    Model D5C-1D@0 D5C-1A@0 Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-car- 2,000 VAC, 50/60 Hz for 1 min between current-car- rying metal parts and non-current-carrying metal rying metal parts and non-current-carrying metal parts parts Rated insulation voltage (U...
  • Page 3: Engineering Data

    Engineering Data Typical Examples Temperature Characteristics of DC Models Temperature Characteristics of AC Models D5C-1D@0 (24 VDC) D5C-1A@0 (100 VAC) With sensitivity adjuster set to minimum sensitivity With sensitivity adjuster set to minimum sensitivity With sensitivity adjuster set to maximum sensitivity...
  • Page 4 Note: 1. Limit the total length of actuator wire to 1 m or less. When mounting the Switch to a metal plate, do not exceed an area of 200 cm 2. Vinyl insulated round cord (oil- and shock-resistant type) 4 dia., three cores y 0.2 mm...
  • Page 5 (Width: 24; thickness: 4) Note: 1. Limit the total length of actuator wire to 1 m or less. When mounting the Switch to a metal plate, do not exceed an area of 200 cm 2. Vinyl insulated round cord (oil- and shock-resistant type) 4 dia., two cores ×...
  • Page 6: Application Examples

    1.0 mm Steel plate 1.0 mm Precautions Refer to the “Precautions for All Switches” in the separate Technical information about Basic Switches or Limit Switches. CAUTION Contact with Non-grounded Conductor Make sure that the antenna does not come into contact with the human body, otherwise an electric The sensing object is equivalently grounded shock may be received.
  • Page 7: Wiring And Connections

    Set point such locations, be sure to take appropriate measures to protect the Be sure to turn the adjuster with a torque of 4.9 to 7.8 mN • m. D5C from oil and water. If excessive torque is applied, the adjuster will break.
  • Page 8 If an appropriate antenna is mounted to a free attachment model, a machinery breakdown will result. Use an isolating transformer and hold the nut on the outer side with a wrench so that the nut will not ground the secondary side of the transformer instead.

This manual is also suitable for:

D5c-1ds0D5c-1dp0D5c-1da0D5c-1as0D5c-1ap0D5c-1aa0 ... Show all

Table of Contents